MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20210298

Медицинская библиотека · The British journal of radiology · 2022

Four-dimensional flow CMR in tetralogy of fallot: current perspectives.

Warmerdam Evangeline Gerdine, Neijzen Rosalie Lucy, Voskuil Michiel, Leiner Tim, Grotenhuis Heynric B

СтатьяОбзорПеревод в очереди

Аннотация

Tetralogy of Fallot is the most common cyanotic congenital heart defect, accounting for 10% of all CHD. Despite most patients now surviving well into adulthood, morbidity and mortality rates continue to be high. Surgical and percutaneous pulmonary valve replacement are procedures that are performed to prevent long-term complications from occurring. Unfortunately, pulmonary valve replacement based on current CMR criteria does not prevent postoperative ventricular arrhythmia, heart failure, and sudden cardiac death. Thus, a more advanced and comprehensive hemodynamic evaluation is needed to better understand right ventricular (dys)function in tetralogy of Fallot patients and to optimize the timing of valve replacement. Recently, four-dimensional flow CMR has emerged as a promising and non-invasive imaging technique that can provide comprehensive quantitative evaluation of flow in an entire volume within the chest in a single imaging session. With velocity-encoding in all three spatial directions throughout the complete cardiac cycle, it can provide analysis of cardiac, pulmonary artery and aortic flow volumes, flow velocities, flow patterns, as well as more advanced hemodynamic parameters. Four-dimensional flow CMR could therefore provide insights into the complex hemodynamics of tetralogy of Fallot and could potentially provide novel criteria for pulmonary valve replacement in these patients. The aim of this review is to provide an overview of available research on four-dimensional flow CMR research in tetralogy of Fallot patients.

Для цитирования: Warmerdam Evangeline Gerdine, Neijzen Rosalie Lucy, Voskuil Michiel, Leiner Tim, Grotenhuis Heynric B. Four-dimensional flow CMR in tetralogy of fallot: current perspectives.. The British journal of radiology. 2022. DOI: 10.1259/bjr.20210298.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.