Comparison of missed adenomas in deep-sedated and unsedated colonoscopy: A multicenter retrospective study.

Sui Yue, Zheng Yanhua, Wang Qing, Lv Jieping, Wang Hongjin, Wen Qing, Wang Zhenzhen, Wang Guanfeng, Jia Hui, Cao Fengzhen, Wang Naping, Hao Junlian, Zhang Yiping, Wu Xiaopeng, Chen Haihua, Lu Junhui, Chen Xing

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Deep-sedated colonoscopy with propofol is widely used in China. However, its impact on quality metrics remains controversial. We aimed to investigate the effects of deep-sedated colonoscopy on missed adenomas, specifically in each colorectal segment.

METHODS

Data of 3710 individuals from seven hospitals in China who underwent an initial colonoscopy with or without propofol sedation and a second colonoscopy without sedation within six months for surveillance or polypectomy by endoscopist of the same level between October 2020 and September 2021 were retrospectively analyzed.

RESULTS

A total of 1113 missed adenomas in 3710 patients were evaluated. The adenoma miss rate (AMR) was significantly higher in deep-sedated colonoscopy than in unsedated colonoscop [19.14% (578/3020) vs. 16.15% (535/3313), P < 0.05]. The risk of missing adenomas in deep-sedated colonoscopy was 1.229 times higher than in unsedated colonoscopy (OR, 1.229; 95% CI: 1.080-1.399). AMRs of the splenic flexure (26.02% [96/369] vs. 16.04% [47/293], P < 0.05) and descending colon (20.86% [102/489] vs. 13.37% [54/404], P < 0.05) were significantly higher in deep-sedated colonoscopy than in unsedated colonoscopy when performed by middle-level endoscopists rather than high-level endoscopists (P < 0.05).

CONCLUSIONS

AMR was higher in deep-sedated colonoscopy than in unsedated colonoscopy. Furthermore, adenomas in the splenic flexure and descending colon were more frequently missed in deep-sedated colonoscopy than in unsedated colonoscopy, particularly when performed by less experienced endoscopists.

Для цитирования: Sui Yue, Zheng Yanhua, Wang Qing, Lv Jieping, Wang Hongjin, Wen Qing, Wang Zhenzhen, Wang Guanfeng, Jia Hui, Cao Fengzhen, Wang Naping, Hao Junlian, Zhang Yiping, Wu Xiaopeng, Chen Haihua, Lu Junhui, Chen Xing. Comparison of missed adenomas in deep-sedated and unsedated colonoscopy: A multicenter retrospective study.. European journal of internal medicine. 2023. DOI: 10.1016/j.ejim.2023.01.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.