Journal of neurophysiology · 2026
Stability of ruthenium oxide-coated microelectrode arrays for chronic stimulation of rat somatosensory cortex.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Smith Thomas J, Srinivasan Hari, Vargas Sophia L, Khajehzadeh Mahasty, Jeakle Eleanor N, Tirumala Kumara Shreya, Jiang Madison, Ogundipe Ashlynn, Villafranca Luisa R, Kaul Mehak, Khan Arlin A, Cheon Claire, Bendea Mihai, Faruk Fareeha, Tahmasebi Ghazaal, Abbott Justin, Barre Andrew, Hernandez-Reynoso Ana G, Pancrazio Joseph J, Cogan Stuart F
Аннотация
Intracortical microstimulation (ICMS) of the primary somatosensory cortex offers the potential for restoring sensory function in neuroprosthetic applications; however, achieving stable long-term performance from implanted electrode materials remains a challenge. Recently, ruthenium oxide (RuOx) has emerged as a viable faradaic coating material suitable for ICMS application due to its high-charge injection capacity, low impedance, and stable electrochemical properties. However, its long-term in vivo performance remains an area of active investigation. In this study, we evaluated the viability of RuOx-coated amorphous silicon carbide microelectrode arrays (MEAs) for producing ICMS-evoked percepts over a 25-wk chronic implantation period with an established rodent-based go/no-go behavioral paradigm. Weekly behavioral, electrochemical, and local electrophysiological measurements were analyzed to assess the stability of RuOx for long-term stimulation and recording studies. Results showed an exponential-like reduction in perception thresholds, stabilizing around the ninth postimplantation week at ∼0.4 nC/ph per electrode ×16 electrodes (simultaneous multichannel stimulation). Throughout this period, behavioral performance remained consistently high (∼91%), with stable reaction times, indicating reliable sensory perception up to 25 wk. Electrochemical measurements, including 1-kHz impedance and driving voltage, alongside neural recording metrics like spike rate and noise floor, remained relatively stable throughout the study. Although minor degradations in the number of detected units per electrode and the peak-to-peak voltages of those units were observed (consistent with other silicon-based MEA studies), RuOx-coated electrodes demonstrated the ability to reliably evoke sensory percepts over the duration of the experiment. Overall, these findings highlight RuOx as a durable MEA-coating material for future ICMS applications.NEW & NOTEWORTHY Ruthenium oxide has emerged as a promising electrode coating material for intracortical microstimulation applications due to its favorable electrochemical properties. However, its long-term in vivo stimulation performance has not been well characterized. Using a go/no-go behavioral paradigm, we show that ruthenium oxide-coated microelectrode arrays support functionally relevant intracortical microstimulation-induced percepts for up to 25 wk postimplantation in rat somatosensory cortex, highlighting stable electrochemical properties and the utility of ruthenium oxide for chronic applications.