MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcdd13090422

Медицинская библиотека · Journal of cardiovascular development and disease · 2026

First-Trimester Assessment of the Extended Fetal Cardiovascular System Using the CASSEAL 3 × 3 Framework: Feasibility, Reproducibility and Diagnostic Performance.

Martínez Payo Cristina, García Nieto Irene, Martínez Ana Jimena Salcedo, Salas Gil Carla, Álvarez Martín Teresa, Gambacorti Zita, Pintado Recarte Pilar, Pena-Burgos Eva Manuela, Ortega Miguel A, De León-Luis Juan, Bravo Arribas Coral

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The Extended Fetal Cardiovascular System (EFCS) encompasses the cardiac, infracardiac, and supracardiac vascular territories that contribute to fetal cardiovascular development and function. The CASSEAL 3 × 3 framework was developed to provide a structured anatomical assessment of the EFCS. This study aimed to evaluate its feasibility, reproducibility, and diagnostic performance during first-trimester screening.

METHODS

In this prospective single-center study, singleton pregnancies undergoing ultrasound examination between 11 + 0 and 13 + 6 weeks of gestation were assessed using the CASSEAL 3 × 3 framework. Feasibility, examination time, use of complementary techniques, interobserver reproducibility, and diagnostic performance were evaluated. Prenatal follow-up and postnatal findings served as the reference standard.

RESULTS

A total of 288 pregnancies were included in the final analysis. Complete visualization of all nine axial views was achieved in 86.5% of examinations. Mean examination time was 12.5 ± 3.3 min. Higher gestational age increased the likelihood of complete visualization, whereas higher maternal body mass index reduced feasibility. Interobserver agreement was high, with no significant systematic differences between operators. Six suspected EFCS abnormalities were identified during first-trimester examination. Diagnostic performance demonstrated high specificity (99.64%) and negative predictive value (98.58%), whereas sensitivity was moderate and should be interpreted cautiously due to the limited number of confirmed abnormalities.

CONCLUSIONS

The CASSEAL 3 × 3 framework is a feasible and reproducible approach for structured first-trimester assessment of the EFCS. Diagnostic performance estimates should be interpreted cautiously given the limited number and spectrum of confirmed abnormalities and the use of a composite reference standard without systematic postnatal echocardiography. The framework may be better suited to specialized fetal medicine settings or as an adjunct to routine first-trimester assessment rather than as a universal screening tool.

Для цитирования: Martínez Payo Cristina, García Nieto Irene, Martínez Ana Jimena Salcedo, Salas Gil Carla, Álvarez Martín Teresa, Gambacorti Zita, Pintado Recarte Pilar, Pena-Burgos Eva Manuela, Ortega Miguel A, De León-Luis Juan, Bravo Arribas Coral. First-Trimester Assessment of the Extended Fetal Cardiovascular System Using the CASSEAL 3 × 3 Framework: Feasibility, Reproducibility and Diagnostic Performance.. Journal of cardiovascular development and disease. 2026. DOI: 10.3390/jcdd13090422.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.