MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bios16090521

Медицинская библиотека · Biosensors · 2026

Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence.

Alsharidah Raghad S, Anwer Razique, Abdelhamid Maysoon Anwar, Alanazi Eman Amer, Alanazi Farah Mfwadh, Alanazi Haneen Fahaid, Alotaibi Jumanah Naif, Alshathri Lama Abdulaziz, Alshehri Renad Ali, Alsuhibani Rania, Majrashi Raghad H

СтатьяСистематический обзорОбзорПеревод в очереди

Аннотация

Background

Wearable sweat biosensors have emerged as a promising non-invasive approach for monitoring inflammatory biomarkers, offering an alternative to repeated blood sampling. This systematic review evaluated the current evidence on the detection of C-reactive protein (CRP), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) in sweat for infection and inflammatory disease monitoring.

Methods

Following PRISMA 2020 guidelines (PROSPERO: CRD420261371221), PubMed/MEDLINE, Scopus, Web of Science, IEEE Xplore, and Google Scholar were searched through April 2026. Human studies measuring CRP, IL-6, or TNF-α in sweat using wearable or biosensor-based platforms were included. Risk of bias and certainty of evidence were assessed using a modified Newcastle-Ottawa Scale/JBI checklist and GRADE.

Results

Thirteen studies (2020-2025, 5-80 participants) were included. CRP showed the most consistent sweat-serum agreement (r = 0.844) and good diagnostic performance in one inflammatory bowel disease cohort (AUC = 0.845). TNF-α demonstrated the highest diagnostic accuracy in a single longitudinal study (AUC = 0.962), whereas IL-6 showed moderate sweat-serum correlations (R2 = 0.60-0.72) but limited diagnostic discrimination. IL-6 and TNF-α were more consistently detected in passively collected eccrine sweat, although IL-6 was also successfully measured following pilocarpine iontophoresis in one study. Most studies had moderate methodological quality.

Conclusions

Sweat-based measurement of CRP, IL-6, and TNF-α is analytically feasible for non-invasive inflammatory biomarker monitoring. However, current evidence remains limited by small, heterogeneous studies, underscoring the need for standardized protocols and larger prospective clinical validation.

Для цитирования: Alsharidah Raghad S, Anwer Razique, Abdelhamid Maysoon Anwar, Alanazi Eman Amer, Alanazi Farah Mfwadh, Alanazi Haneen Fahaid, Alotaibi Jumanah Naif, Alshathri Lama Abdulaziz, Alshehri Renad Ali, Alsuhibani Rania, Majrashi Raghad H. Wearable Sweat Biosensors for Inflammatory Biomarkers (CRP, IL-6 and TNF-α): A Systematic Review of Analytical and Clinical Evidence.. Biosensors. 2026. DOI: 10.3390/bios16090521.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.