MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jcecho.jcecho_14_26

Медицинская библиотека · Journal of cardiovascular echography · 2026

Three-dimensional Evaluation of Atrioventricular Valve Geometry in the Fetal Heart: Establishing Reference Standards and Clinical Validation.

Nogueira Tassyele Pamplona, Callado Gustavo Yanno, Bravo-Valenzuela Nathalie Jeanne, Araujo Júnior Edward

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To establish the reference values for the angle between the atrioventricular (AV) valve insertion levels in fetal hearts using three-dimensional ultrasound with Spatio-temporal Image Correlation (STIC) rendering and to validate these values in fetuses with confirmed congenital heart disease (CHD).

MATERIALS AND

METHODS

A retrospective cross-sectional study was conducted using 59 STIC volumes from structurally normal fetuses between 20 and 33 + 6 weeks of gestation. The AV valve insertion angle was measured in the rendering mode of four-chamber view. A polynomial regression model was used to generate a reference curve and percentile table. A validation cohort of 26 fetuses with CHD was analyzed, and angle distributions were compared with the normative percentiles.

RESULTS

The insertion angle remained stable throughout gestation. Reference percentiles (5th, 10th, 50th, 90th, and 95th) were established by gestational week. Among fetuses with CHD, 46.2% had angles below the 5th percentile and 57.7% above the 95th percentile, with only 7.7% within the normal range. Specific CHD such as tetralogy of Fallot, transposition of the great arteries, and truncus arteriosus showed consistent deviations from normal values.

CONCLUSION

The AV valve insertion angle was a stable parameter throughout gestation and demonstrates significant deviation in fetuses with CHD. This measurement may serve as a useful screening tool for early prenatal identification of certain structural CHD.

Для цитирования: Nogueira Tassyele Pamplona, Callado Gustavo Yanno, Bravo-Valenzuela Nathalie Jeanne, Araujo Júnior Edward. Three-dimensional Evaluation of Atrioventricular Valve Geometry in the Fetal Heart: Establishing Reference Standards and Clinical Validation.. Journal of cardiovascular echography. 2026. DOI: 10.4103/jcecho.jcecho_14_26.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.