Journal of pediatric endocrinology & metabolism : JPEM · 2025
Pitfalls in the diagnosis of carnitine palmitoyltransferase 1 deficiency.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Grünert Sarah C, Berger Urs, Hörster Friederike, Schwarz Kathrin, Thimm Eva, Spiekerkoetter Ute, Haas Dorothea, Schumann Anke
Аннотация
OBJECTIVES: Carnitine palmitoyltransferase 1 A (CPT1A) deficiency is an ultra-rare autosomal recessive disorder of the carnitine cycle caused by biallelic pathogenic variants in the CPT1A gene. It mainly presents with a hepatic phenotype and is a target disease of newborn screening programs worldwide. Disease-specific and diagnostic abnormalities of CPT1A deficiency comprise elevated concentrations of free carnitine as well as an elevated metabolite ratio [C0/(C16 + C18)] in blood, but the ideal sample material has been a matter of debate.
METHODS: We present biochemical data of five CPT1A deficient patients, of whom four were diagnosed by newborn screening from dried blood spots.
RESULTS: Our cases demonstrate that acylcarnitine profiles and especially concentrations of free carnitine can be normal in plasma in infants with CPT1AD at confirmation diagnosis after screening and during follow-up. Even the [C0/(C16 + C18)] ratio yielded normal results in some cases.
CONCLUSIONS: Our data show, that dried blood is the preferred sample material for the diagnosis of CPT1A deficiency as it is superior to serum/plasma with respect to diagnostic sensitivity and reliability in quantification of the ratio [C0/(C16 + C18)]. CPT1A deficiency can be missed, if the analysis is only performed in serum or plasma, and confirmatory diagnostics in serum or plasma after screening can be false negative.
METHODS: We present biochemical data of five CPT1A deficient patients, of whom four were diagnosed by newborn screening from dried blood spots.
RESULTS: Our cases demonstrate that acylcarnitine profiles and especially concentrations of free carnitine can be normal in plasma in infants with CPT1AD at confirmation diagnosis after screening and during follow-up. Even the [C0/(C16 + C18)] ratio yielded normal results in some cases.
CONCLUSIONS: Our data show, that dried blood is the preferred sample material for the diagnosis of CPT1A deficiency as it is superior to serum/plasma with respect to diagnostic sensitivity and reliability in quantification of the ratio [C0/(C16 + C18)]. CPT1A deficiency can be missed, if the analysis is only performed in serum or plasma, and confirmatory diagnostics in serum or plasma after screening can be false negative.