BACKGROUND

Aortic stenosis (AS) can cause acquired von Willebrand syndrome (AVWS) and valve replacement has been shown to lead to von Willebrand factor (vWF) recovery. The aim of the current study was to investigate the prevalence of AVWS in different severe AS phenotypes and its course after transcatheter aortic valve implantation (TAVI).

METHODS

143 patients with severe AS undergoing TAVI were included in the study. vWF function was assessed at baseline, 6 and 24 h after TAVI. AVWS was defined as a reduced vWF:Ac/Ag ratio ≤ 0.7. Phenotypes were classified by tricuspid (TAV) and bicuspid (BAV) valve morphology, mean transvalvular gradient (Pmean), stroke volume index (SVI), ejection fraction (EF) and indexed effective orifice area (iEOA).

RESULTS

AVWS was present in 36 (25.2%) patients before TAVI. vWF:Ac/Ag ratio was significantly lower in high gradient compared to low-gradient severe AS [0.78 (IQR 0.67-0.86) vs. 0.83 (IQR 0.74-0.93), p < 0.05] and in patients with BAV compared to TAV [0.70 (IQR 0.63-0.78) vs. 0.81 (IQR 0.71-0.89), p < 0.05]. Normalization of vWF:Ac/Ag ratio was achieved in 61% patients 24 h after TAVI. As in the overall study cohort, vWF:Ac/Ag ratio increased significantly in all severe AS subgroups 6 h after TAVI (each p < 0.05). Regarding binary logistic regression analysis, BAV was the only significant predictor for AVWS.

CONCLUSIONS

BAV morphology is a strong predictor for AVWS in severe AS. TAVI restores vWF function in most patients with severe AS independently of AS phenotype and valve morphology.

Для цитирования: Roth Nastasia, Heidel Carolin, Xu Congde, Hubauer Ute, Wallner Stefan, Meindl Christine, Holzamer Andreas, Hilker Michael, Creutzenberg Marcus, Sossalla Samuel, Maier Lars, Jungbauer Carsten, Debl Kurt. The impact of bicuspid aortic valve morphology on von Willebrand factor function in patients with severe aortic stenosis and its change after TAVI.. Clinical research in cardiology : official journal of the German Cardiac Society. 2022. DOI: 10.1007/s00392-022-02047-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.