MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2020-015909

Медицинская библиотека · Journal of neurointerventional surgery · 2020

Four-dimensional digital subtraction angiography for exploration of spinal cord vascular malformations: preliminary experience.

Clarençon Frédéric, Lenck Stéphanie, Shotar Eimad, Boch Anne-Laure, Lefevre Etienne, Premat Kevin, Amador Maria Del Mar, Sourour Nader-Antoine

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The precise understanding of the angioarchitecture of spinal vascular malformations (SVMs) is often difficult to reach with conventional digital subtraction angiography (DSA). The purpose of our study was to evaluate the potential of four-dimensional DSA (4D-DSA) (Siemens Healthcare) in the exploration of SVMs.

METHODS

We retrospectively studied all patients who underwent spinal DSA, including 4D-DSA acquisition, from July 2018 to June 2019 at a single institution. All spinal DSA acquisitions were performed under general anesthesia. 4D-DSA acquisitions were acquired with the protocol '12 s DSA Dyna4D Neuro'. 12 mL of iodixanol 320 mg iodine/mL were injected via a 5 F catheter (1 mL/s during the 12 s 4D-DSA acquisition). Inter-rater (three independent reviewers) and intermodality agreements were assessed.

RESULTS

Nine consecutive patients (six men, three women, mean age 55.3±19.8 years) with 10 SVMs (spinal dural arteriovenous fistulas n=3, spinal epidural arteriovenous fistulas n=2, spinal pial arteriovenous fistulas n=2, and spinal arteriovenous malformations n=2; one patient had two synchronous pial fistulas) had spinal DSA, including 4D-DSA acquisition. Inter-rater agreement was good and moderate for the venous drainage pattern and the SVM subtype, respectively. In 9 of 10 cases, the quality of the acquisition was graded as good. Satisfactory concordance between 4D-DSA and the selective microcatheterization was observed in 90% of cases for the location of the shunt point.

CONCLUSION

4D-DSA acquisition may be helpful for a better understanding of the angioarchitecture of SVMs. Larger series are warranted to confirm these preliminary results.

Для цитирования: Clarençon Frédéric, Lenck Stéphanie, Shotar Eimad, Boch Anne-Laure, Lefevre Etienne, Premat Kevin, Amador Maria Del Mar, Sourour Nader-Antoine. Four-dimensional digital subtraction angiography for exploration of spinal cord vascular malformations: preliminary experience.. Journal of neurointerventional surgery. 2020. DOI: 10.1136/neurintsurg-2020-015909.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.