BACKGROUND
When performing a vaginal hysterectomy, removal of the tubes and ovaries can be either necessary or desirable. We describe our experience with a new instrument called the Gupta-Frank clamp for performing vaginal salpingo-oophorectomy at the time of vaginal hysterectomy.
INSTRUMENT: The stainless steel Gupta-Frank clamp is 260 mm long, and its shanks are curved to avoid impedance from the vaginal walls. The 70-mm jaws have a smooth curve, which allows both the round and infundibulopelvic ligaments to be incorporated into a single clamp bite. Each jaw has three serrated grooves, which interlock with the corresponding jaw grooves to give a 6-mm-wide atraumatic nonslip area.
EXPERIENCE: We have used this instrument in 18 women undergoing bilateral salpingo-oophorectomy at the time of vaginal hysterectomy. A single clamp bite on each side was sufficient to accomplish salpingo-oophorectomy in all cases. There were no major complications.
CONCLUSION
Salpingo-oophorectomy performed vaginally at the time of vaginal hysterectomy with the Gupta-Frank clamp is feasible and is accomplished easily and safely.