MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1051-0443(07)61562-0

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2001

Aortic intimal dehiscence: a complication of percutaneous balloon fenestration for aortic dissection.

Lookstein R A, Mitty H, Falk A, Guller J, Nowakowski F S

Клинический случайСтатьяПеревод в очереди

Аннотация

A patient with acute type B dissection and a tube configuration of the intimal flap presented with signs of advanced mesenteric and renal ischemia as well as decreased pulses in the lower extremities. The patient was referred for emergency percutaneous fenestration of the abdominal aorta as a salvage procedure and a possible bridge to later surgery. After fenestration, femoral pulses became transiently stronger and then disappeared. The patient died after exploratory laparotomy. Postmortem examination demonstrated dehiscence of the infrarenal abdominal aortic intima with occlusion of the aortic bifurcation.

Для цитирования: Lookstein R A, Mitty H, Falk A, Guller J, Nowakowski F S. Aortic intimal dehiscence: a complication of percutaneous balloon fenestration for aortic dissection.. Journal of vascular and interventional radiology : JVIR. 2001. DOI: 10.1016/s1051-0443(07)61562-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.