MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000044196

Медицинская библиотека · Medicine · 2025

In vivo quantitative assessment of atherosclerotic plaque: A validation study on the optical coherence tomography-derived index of plaque attenuation.

Cai Xingxuan, Cao Yihui, Lu Quanmao, Jing Jing, Wei Kai, Hu Yingyun, Wang Mingyi, Zhou Shanshan, Chen Yundai

СтатьяНаблюдательное исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

Growing evidence indicates that coronary plaque instability is an independent risk factor for adverse coronary events, yet current optical coherence tomography (OCT) assessment of high-risk plaque characteristics (HRPC) relies largely on qualitative interpretation. The index of plaque attenuation (IPA) is a quantitative OCT-based metric that may provide a more objective evaluation. This retrospective observational diagnostic accuracy study assessed the performance of OCT-derived IPA for HRPC detection in patients with acute coronary syndrome or stable angina, using expert consensus qualitative OCT analysis as the reference standard. A total of 560 analyzable OCT cross-sections from 83 patients were categorized as HRPC or non-HRPC, with the latter grouped into progression plaque characteristics (PPC) or normal vessels. Receiver operating characteristic analysis was performed. IPA11 distinguished HRPC from non-HRPC with an area under the curve of 0.75 (95% confidence interval: 70.3-79.0; P < .001), sensitivity of 76.1%, and specificity of 63.8%. IPA11 was higher in HRPC than in non-HRPC (66.0 [38.0-110.0] vs 20.0 [2.0-52.0]; P = .001). In the non-HRPC group, IPA8 differentiated PPC from normal vessels with an area under the curve of 0.98 (95% CI: 95.3-98.8; P < .001), with higher values in PPC (241.0 [155.5-320.5] vs 11.0 [3.5-30.5]; P < .001). IPA offers an objective, quantitative method for automated OCT-based plaque assessment, demonstrating good accuracy for HRPC identification and excellent discrimination of PPC from normal vessels, meriting validation in larger prospective studies.

Для цитирования: Cai Xingxuan, Cao Yihui, Lu Quanmao, Jing Jing, Wei Kai, Hu Yingyun, Wang Mingyi, Zhou Shanshan, Chen Yundai. In vivo quantitative assessment of atherosclerotic plaque: A validation study on the optical coherence tomography-derived index of plaque attenuation.. Medicine. 2025. DOI: 10.1097/md.0000000000044196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.