MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mayocp.2018.07.008

Медицинская библиотека · Mayo Clinic proceedings · 2018

Diagnostic Utility of Complement Serology for Atypical Hemolytic Uremic Syndrome.

Sridharan Meera, Go Ronald S, Abraham Roshini S, Fervenza Fernando C, Sethi Sanjeev, Bryant Sandra C, Spears Grant M, Murray David L, Willrich Maria A V

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the clinical utility of a 9-analyte complement serology panel (COMS) covering complement function (CH50 and AH50), components (C3, C4), factor B (CFB), factor H, and activation markers (C4d, Bb, and soluble membrane attack complex) for the diagnosis of atypical hemolytic uremic syndrome (aHUS).

METHODS

Physician orders for COMS from January 19, 2015, through November 4, 2016, were reviewed. Demographic characteristics, patient diagnosis, and laboratory parameters were recorded.

RESULTS

There were 177 COMS orders for 147 patients. The median patient age was 44.9 years (range, 0.9-88.0 years). Common reasons for ordering COMS included monitoring and diagnosis of C3 glomerulopathy and renal dysfunction and differentiation of aHUS from other thrombotic microangiopathies (TMAs). Forty-four patients had COMS ordered for TMAs: 8 had aHUS and all had 1 or more abnormalities within the alternative pathway of complement. Although the sensitivity of this finding for the diagnosis of aHUS is 100%, the specificity is only 28%, with a positive likelihood ratio of 1.39. Patients with aHUS had lower CH50, C3, and CFB than did those with secondary non-aHUS TMA (all P<.01). A combined CFB of 20.9 mg/dL or less and CH50 of 56% or less led to sensitivity of 75% with increased specificity of 88.9% and a diagnostic odds ratio of 24.

CONCLUSION

A COMS abnormality should not be interpreted in isolation. In conjunction with clinical presentation, a decrease in both CFB and CH50 may be an important clue to support the diagnosis of aHUS.

Для цитирования: Sridharan Meera, Go Ronald S, Abraham Roshini S, Fervenza Fernando C, Sethi Sanjeev, Bryant Sandra C, Spears Grant M, Murray David L, Willrich Maria A V. Diagnostic Utility of Complement Serology for Atypical Hemolytic Uremic Syndrome.. Mayo Clinic proceedings. 2018. DOI: 10.1016/j.mayocp.2018.07.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.