MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msec.2020.110661

Медицинская библиотека · Materials science & engineering. C, Materials for biological applications · 2020

Thermal stimuli-responsive hyaluronic acid loaded cellulose based physical hydrogel for post-surgical de novo peritoneal adhesion prevention.

Sultana Tamanna, Gwon Jae-Gyoung, Lee Byong-Taek

СтатьяПеревод в очереди

Аннотация

Effective strategies for post-surgical adhesion prevention have increasingly focused on injectable adhesion barriers due to their minimal invasiveness and wider applicability. In this study, a thermo-reversible hydrogel was developed by combining high molecular weight hyaluronic acid (HA) at various concentrations (0.05, 0.25, and 0.45% w/v) with tempo-oxidized nanocellulose (TOCN), methyl cellulose (MC) and polyethylene glycol (PEG) for anti-adhesion application. The hydrogel preparation time was short and did not require any chemical modification. TOCN ensured the mechanical stability of the hydrogel. MC confirmed thermo-sensitive feature. Higher amounts of HA increased the rate of hydrogel degradation. The HA 0.25 hydrogel was free-flowing, injectable at ambient temperature, capable of faster (40 ± 2 s), and reversible sol-gel (4 °C-37 °C) transition. A rat side-wall cecum abrasion model was used to confirm the complete de novo adhesion prevention efficacy of optimized HA 0.25 hydrogel, where the scratched abdominal wall of animals treated with HA 0.25 hydrogel healed after 14 days. During in vivo experiment, PEG in the hydrogel played a crucial role in adhesion prevention by minimizing friction between the surgical site and nearby organs. In a nutshell, HA 0.25 hydrogel, fabricated without crosslinking agent, is a potential candidate for tissue adhesion prevention strategies.

Для цитирования: Sultana Tamanna, Gwon Jae-Gyoung, Lee Byong-Taek. Thermal stimuli-responsive hyaluronic acid loaded cellulose based physical hydrogel for post-surgical de novo peritoneal adhesion prevention.. Materials science & engineering. C, Materials for biological applications. 2020. DOI: 10.1016/j.msec.2020.110661.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.