MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2026.100918

Медицинская библиотека · Physics and imaging in radiation oncology · 2026

A combined automatic organ at risk contouring and synthetic Computed Tomography solution for pelvic Magnetic Resonance-only radiotherapy.

Wyatt Jonathan J, Kaushik Sandeep, Cozzini Cristina, Kolozsvári Bernadett, Deák-Karancsi Borbála, Pearson Rachel A, Petit Steven, Capala Marta, Hernandez-Tamames Juan A, Hideghéty Katalin, Maxwell Ross J, Ruskó László, Wiesinger Florian, McCallum Hazel M

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Magnetic Resonance (MR)-only radiotherapy improves treatment accuracy and efficiency but requires a synthetic Computed Tomography (sCT) for dose calculations. Automatic MR-based Organs At Risk (OARs) contouring could further improve consistency and efficiency. A combined automatic MR OAR contouring and sCT solution has been developed, with each component separately validated. This study aimed to evaluate this combined MR-only workflow against a manual MR-CT workflow for pelvic cancers.

MATERIALS AND

METHODS

Radiotherapy MR and CT scans were acquired for 20 patients (10 prostate, 4 rectum, 6 anus cancer). The MR-only workflow used sCTs and automatic contours for the bladder, bowel bag, femoral heads, rectum, penile bulb, prostate, seminal vesicles and urethra along with manual target contours to optimise a MR-only plan. Doses were compared to the current clinical standard of deformably registered CT and manual MR OAR contours (MR-CT).

RESULTS

Mean dose differences were ≤ 1 Gy ; 1 percentage point relative volume for all OARs except the bowel bag. Mean absolute dose differences were also ≤ 1 Gy for all OARs except bowel bag in ano-rectal patients and except bowel bag, bladder V 50 Gy , V 40 Gy , V 30 Gy and rectum V 30 Gy in prostate patients.

CONCLUSIONS

The automatic MR OAR contouring and sCT workflow had similar dose differences to manual inter-observer variability for all OARs except the lower dose bladder and rectum volumes (prostate patients only) and bowel bag (prostate and ano-rectal patients). This combined OAR contouring and MR-only workflow could enable more efficient and consistent pelvic radiotherapy treatment.

Для цитирования: Wyatt Jonathan J, Kaushik Sandeep, Cozzini Cristina, Kolozsvári Bernadett, Deák-Karancsi Borbála, Pearson Rachel A, Petit Steven, Capala Marta, Hernandez-Tamames Juan A, Hideghéty Katalin, Maxwell Ross J, Ruskó László, Wiesinger Florian, McCallum Hazel M. A combined automatic organ at risk contouring and synthetic Computed Tomography solution for pelvic Magnetic Resonance-only radiotherapy.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.100918.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.