MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jocs.16460

Медицинская библиотека · Journal of cardiac surgery · 2022

Rotation characteristics and neo-commissural alignment of transcatheter heart valve in type-0 bicuspid aortic valve.

Chen Mi, Ding Yan, Zhao Honglei, Pu Junzhou, Yang Bo, Qiao Huanyu, Zhang Wei, Bai Tao, Xue Jinrong, Wu Wenhui, Liu Yongmin, Sun Lizhong, Zhang Haibo

СтатьяПеревод в очереди

Аннотация

AIMS: This study sought to characterize the rotation of the transcatheter heart valve (THV) and evaluate the neo-commissures overlap with coronary arteries in type-0 bicuspid aortic valve (BAV).

METHODS AND

RESULTS

This was a single-center, 10-patient, retrospective observational cohort. Pre-TAVI computed tomography and procedural fluoroscopy were analyzed. Coplanar fluoroscopic views were coregistered to pre-TAVI computed tomography to characterize THV rotation and determine coronary overlap. The incidence of severe coronary artery overlap with one coronary artery was 90%. According to our prediction line, type-0 BAV has predicted a higher incidence of overlap with one coronary artery, but lower incidence with both coronary arteries compared to the tricuspid aortic valve (TAV). The rotational angles in two different phases were 3.8 ± 3.2° versus 11.8 ± 8.0° (p = .01) in patients with mixed cusp fusion. Commissural angles in final and initial deployment were 9.6 ± 6.6 versus 18.1 ± 11.0° (p = .021). Applying hypothetic "commissure-middle view" in 0°, ±5°, and ±10°, the incidence of overlap with one coronary artery are 20%, 40%, and 90% separately.

CONCLUSIONS

The THV rotation existed and was activated in the last 1/3 deploying phase. With the observed tendency of "automatic commissural alignment," applying the "commissure-middle" view in type-0 BAV may optimize valve alignment and avoid coronary artery overlap.

Для цитирования: Chen Mi, Ding Yan, Zhao Honglei, Pu Junzhou, Yang Bo, Qiao Huanyu, Zhang Wei, Bai Tao, Xue Jinrong, Wu Wenhui, Liu Yongmin, Sun Lizhong, Zhang Haibo. Rotation characteristics and neo-commissural alignment of transcatheter heart valve in type-0 bicuspid aortic valve.. Journal of cardiac surgery. 2022. DOI: 10.1111/jocs.16460.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.