MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0251880

Медицинская библиотека · PloS one · 2021

Development and ex-vivo assessment of a novel patient specific guide and instrumentation system for minimally invasive total shoulder arthroplasty.

Giles Joshua W, Brodén Cyrus, Tempelaere Christine, Emery Roger J H, Rodriguez Y Baena Ferdinando

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To develop and assess a novel guidance technique and instrumentation system for minimally invasive short-stemmed total shoulder arthroplasty that will help to reduce the complications associated with traditional open replacement such as poor muscle healing and neurovascular injury. We have answered key questions about the developed system including (1) can novel patient-specific guides be accurately registered and used within a minimally invasive environment?; (2) can accuracy similar to traditional techniques be achieved?

METHODS

A novel intra-articular patient-specific guide was developed for use with a new minimally invasive posterior surgical approach that guides bone preparation without requiring muscle resection or joint dislocation. Additionally, a novel set of instruments were developed to enable bone preparation within the minimally invasive environment. The full procedure was evaluated in six cadaveric shoulders, using digitizations to assess accuracy of each step.

RESULTS

Patient-specific guide registration accuracy in 3D translation was 2.2±1.2mm (RMSE±1 SD; p = 0.007) for the humeral component and 2.7±0.7mm (p<0.001) for the scapula component. Final implantation accuracy was 2.9±3.0mm (p = 0.066) in translation and 5.7-6.8±2.2-4.0° (0.001<p<0.009) across the humerus implants' three rotations. Similarly, the glenoid component's implantation accuracy was 3.0±1.7mm (p = 0.008) in translation and 2.3-4.3±2.2-4.4° (0.008<p<0.09) in rotation.

CONCLUSION

This system achieves minimally invasive shoulder replacement with accuracy similar to traditional open techniques while avoiding common causes of complications.

SIGNIFICANCE: This novel technique could lead to a paradigm shift in shoulder arthroplasty for patients with moderate arthritis, which could significantly improve rehabilitation and functional outcomes.

Для цитирования: Giles Joshua W, Brodén Cyrus, Tempelaere Christine, Emery Roger J H, Rodriguez Y Baena Ferdinando. Development and ex-vivo assessment of a novel patient specific guide and instrumentation system for minimally invasive total shoulder arthroplasty.. PloS one. 2021. DOI: 10.1371/journal.pone.0251880.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.