MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-23-00779

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024

Comparison of two self-expanding transcatheter heart valves for degenerated surgical bioprostheses: the AVENGER multicentre registry.

Kim Won-Keun, Seiffert Moritz, Rück Andreas, Leistner David M, Dreger Henryk, Wienemann Hendrik, Adam Matti, Möllmann Helge, Blumenstein Johannes, Eckel Clemens, Buono Andrea, Maffeo Diego, Messina Antonio, Holzamer Andreas, Sossalla Samuel, Costa Giuliano, Barbanti Marco, Motta Silvia, Tamburino Corrado, von der Heide Ina, Glasmacher Julius, Sherif Mohammad, Seppelt Philipp, Fichtlscherer Stephan, Walther Thomas, Castriota Fausto, Nerla Roberto, Frerker Christian, Schmidt Tobias, Wolf Alexander, Adamaszek Martin M, Giannini Francesco, Vanhaverbeke Maarten, Van de Walle Stefaan, Stammen Francis, Toggweiler Stefan, Brunner Stephanie, Mangieri Antonio, Gitto Mauro, Kaleschke Gerrit, Ninios Vlasis, Ninios Ilias, Hübner Judith, Xhepa Erion, Renker Matthias, Charitos Efstratios I, Joner Michael, Rheude Tobias

Многоцентровое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]).

AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV.

METHODS

In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching.

RESULTS

The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients.

CONCLUSIONS

ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.

Для цитирования: Kim Won-Keun, Seiffert Moritz, Rück Andreas, Leistner David M, Dreger Henryk, Wienemann Hendrik, Adam Matti, Möllmann Helge, Blumenstein Johannes, Eckel Clemens, Buono Andrea, Maffeo Diego, Messina Antonio, Holzamer Andreas, Sossalla Samuel, Costa Giuliano, Barbanti Marco, Motta Silvia, Tamburino Corrado, von der Heide Ina, Glasmacher Julius, Sherif Mohammad, Seppelt Philipp, Fichtlscherer Stephan, Walther Thomas, Castriota Fausto, Nerla Roberto, Frerker Christian, Schmidt Tobias, Wolf Alexander, Adamaszek Martin M, Giannini Francesco, Vanhaverbeke Maarten, Van de Walle Stefaan, Stammen Francis, Toggweiler Stefan, Brunner Stephanie, Mangieri Antonio, Gitto Mauro, Kaleschke Gerrit, Ninios Vlasis, Ninios Ilias, Hübner Judith, Xhepa Erion, Renker Matthias, Charitos Efstratios I, Joner Michael, Rheude Tobias. Comparison of two self-expanding transcatheter heart valves for degenerated surgical bioprostheses: the AVENGER multicentre registry.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2024. DOI: 10.4244/eij-d-23-00779.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.