INTRODUCTION

Restoration of dental rehabilitation is the ultimate goal of functional jaw reconstruction, which is called "occlusion-driven jaw reconstruction", whereas fibular mandibular reconstruction (FMR) in the Asian population fails to adequately provide adequate bone volume for subsequent dental implantation. This study proposed a preoperative occlusion-driven design of FMR and compared the peri-implant bone thickness in fibular-reconstructed mandibles with or without preoperative occlusion-driven design.

METHODS

The patients underwent FMR and following dental implantation were reviewed, consisting of 10 cases with preoperative occlusion-driven design of free fibular flap (FFF) as the experimental group and the other 12 cases as the control group. A total of 82 endosseous implants were radiographically evaluated and the cross-sectional buccal, lingual, and bottom distances between implant and fibula were calculated.

RESULTS

The lingual bone thickness at the crown third of the peri-implant in the premolar region and at the middle third of the peri-implant in the molar region was 2.36±0.36 and 4.90±0.43 mm in the experimental group, significantly greater than 1.57±0.15 and 3.73±0.32 mm in the control group, respectively (P=0.04, P=0.032). The bone thickness at the root of the peri-implant in the experimental group was significantly greater than that in the control group (P=0.007). Specifically, the anterior and premolar regions in the experimental group were 4.31±0.24 and 4.29±0.30 mm, significantly greater than 3.21±0.40 and 4.16±0.30 mm in the control group, respectively (P=0.019 and P=0.009). No significant difference was found in the buccal bone thickness at the crown, middle, and root third of the peri-implant between the experimental and control groups.

CONCLUSIONS

On the basis of the results of limited cases, this study demonstrated preoperative occlusion-driven design of the intended fibula segment for implant placement could provide adequate bone volume for endosseous implants, contributing to maximize successful osseointegration and minimize complications for FMR patients.

Для цитирования: Miao Dongqing, Cao Jikang, Zhou Haifei, Wang Zhuo, Bian Yifeng, Yu Yi, Wan Linzhong, Yuan Hua, Du Yifei, Wang Yuli. Radiographic Evaluation of Peri-Implant Bone Thickness in Fibular Mandible Reconstruction With Preoperative Occlusion-Driven Design.. The Journal of craniofacial surgery. 2026. DOI: 10.1097/scs.0000000000013076.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.