Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation.

Fiszer Roland, Dryżek Paweł, Szkutnik Małgorzata, Góreczny Sebastian, Krawczuk Alexandra, Moll Jadwiga, Moszura Tomasz, Pawlak Szymon, Białkowski Jacek

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Transcutaneous pulmonary valve replacement (TPVR) has become an alternative to heart surgery for patients after previous right ventricular outflow tract (RVOT) or pulmonary artery (PA) surgical interventions. The objective was to present immediate and long-term outcomes of trans¬cutaneous pulmonary valve replacement.

METHODS

Between 06/2009 and 06/2016, 46 patients underwent TPVR. Initial diagnoses included tetralogy of Fallot, common arterial trunk, transposition of great arteries post Rastelli correction, left ventricle outflow obstruction after Ross operation, pulmonary atresia, and isolated dysplastic pulmonary valve stenosis. Thirty eight (78%) patients had previously implanted conduits in the pulmonary position, the rest had either RVOT patch reconstruction (n = 6; 13%) or biological valve implantation (n = 2; 4%). They presented primarily with pulmonary stenosis (n = 18; 39%) or regurgitation (n = 28; 60%).

RESULTS

All procedures were successful - 44 Melody and 2 Edwards-Sapien valves were implanted. Before each procedure exclusion of potential coronary compression and RVOT prestenting was performed. Significant RVOT systolic gradient reduction (from 35.3 ± 19.5 to 13.5 ± 7.1 mm Hg; p < 0.001) and decrease of right to left ventricle systolic pressure ratio from 0.58 ± 0.18 to mean 0.37 ± 0.1 (p < 0.001) was achieved. Also, in every patient PA-RVOT competence was restored, with minor in¬competence in only a few patients. Post procedure follow-up ranged from 2 to 86 (mean 35.2) months. Follow-up fluoroscopy or chest X-ray revealed 6 stent fractures (2 stent defragmentation - with only 1 significant valve stenosis).

CONCLUSIONS

Transcutaneous pulmonary valve replacement is a safe procedure with encouraging results, it also enables deferring surgical reintervention in the majority of patients.

Для цитирования: Fiszer Roland, Dryżek Paweł, Szkutnik Małgorzata, Góreczny Sebastian, Krawczuk Alexandra, Moll Jadwiga, Moszura Tomasz, Pawlak Szymon, Białkowski Jacek. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation.. Cardiology journal. 2017. DOI: 10.5603/cj.a2017.0023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.