MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s22103681

Медицинская библиотека · Sensors (Basel, Switzerland) · 2022

4-Dimethylaminoantipyrine as a Broad Electrochemical Indicator for Immunosensors Platform.

Melo Francielli C C, Alves Renata P, Valle Anderson L, Santos Fabiana de A A, Dias Ana Carolina S, Goulart Isabela M B, Oliveira Eduardo G A, Oliveira Guedmiller S, Rodrigues Luciano P, Goulart Luiz R

СтатьяПеревод в очереди

Аннотация

Here, we describe 4-dimethylaminoantipyrine (4-DMAA)-mediated interfacing as a broad biochemical indicator to stabilize and promote the higher response of electrodes for immunological detection. We hypothesized that the improved biological interactions of 4-DMAA with electrodes and biological samples may be due to the interaction properties of the benzene and pyrazole chemical groups with graphite and proteins, respectively. In order to demonstrate that 4-DMAA could be used as a general indicator in electrochemical immunoassays, we used peptides as probes for the diagnosis of four neglected tropical infectious diseases Tegumentary leishmaniasis, Visceral leishmaniasis, Strongyloidiasis, and Leprosy on commercial graphite screen-printed electrodes. 4-DMAA oxidation was used to indicate specific biological recognition between the epitope-based peptide and serum immunoglobulin G (IgG) from infected patients. We demonstrated that 4-DMAA should be incorporated into the electrodes prior to serum application, which avoids interference with its sensitivity and specificity. In addition, 4-DMAA oxidizes at a low anodic potential, and the oxidation peak is useful for detecting proteins in biological fluids. In summary, we have successfully demonstrated the broad application of 4-DMAA as a general indicator for the specific diagnosis of four infectious diseases in electrochemical immunosensors. Such a strategy is quite advantageous for indirect detection of proteins that lack electrochemical activities or are spatially inaccessible on the electrode surface. This new indicator opens a new avenue for monitoring biological recognition, especially for immunosensors.

Для цитирования: Melo Francielli C C, Alves Renata P, Valle Anderson L, Santos Fabiana de A A, Dias Ana Carolina S, Goulart Isabela M B, Oliveira Eduardo G A, Oliveira Guedmiller S, Rodrigues Luciano P, Goulart Luiz R. 4-Dimethylaminoantipyrine as a Broad Electrochemical Indicator for Immunosensors Platform.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22103681.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.