Dual-layer spectral detector CT for improved assessment of right adrenal vein in patients with primary aldosteronism.

Yoshida Ryuya, Nagayama Yasunori, Esaki Takumi, Matsumoto Taiga, Tamura Yoshitaka, Ishiuchi Soichiro, Inoue Taihei, Sakabe Daisuke, Igarashi Yasuaki, Kidoh Masafumi, Oda Seitaro, Nakaura Takeshi, Kiyosue Hiro, Hirai Toshinori

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate whether virtual-monoenergetic images (VMI) from dual-layer spectral-detector computed tomography (DLCT) improve right adrenal vein (RAV) assessment before adrenal venous sampling (AVS), and portal-venous-phase (PVP) images alone can replace conventional multiphase CT combining late-arterial phase (LAP) and PVP.

METHODS

Sixty-three patients with primary aldosteronism who underwent LAP and PVP DLCT before AVS were retrospectively analyzed. Conventional polyenergetic-images (PEI) and VMI at 40-70 keV (VMI40-70) were reconstructed. Image noise and contrast-to-noise ratio (CNR) of RAV were quantified. VMI with the highest CNR was predefined as the best-VMI. Two radiologists evaluated four image series (PEI and best-VMI at LAP and PVP) separately for RAV visibility, accessory hepatic vein (AHV) assessability, and image noise using five-point scales (1 = worst, 5 = best). RAV detection and AHV assessability rates were compared among image series.

RESULTS

In both enhancement phases, VMI40-70 showed lower image noise and VMI40-60 higher CNR than PEI (all p < 0.05), with VMI40 providing the highest CNR and being designated as the best VMI. Compared to PEI at LAP, CNR was lower with PEI at PVP but higher with VMI40 at PVP (both, p < 0.001). In subjective analysis, VMI40 showed better scores than PEI for image noise (LAP: 4.0 ± 0.5 vs. 2.4 ± 0.6; PVP: 4.0 ± 0.6 vs. 2.5 ± 0.5) and RAV visibility (LAP: 4.5 ± 0.8 vs. 3.5 ± 0.8; PVP: 3.7 ± 1.0 vs. 2.6 ± 0.9) (all p < 0.001). With PEI, the RAV detection rate was lower at PVP than at LAP (54.8% vs. 89.7%, p < 0.001). Use of VMI40 at PVP achieved the same detection rate as PEI at LAP (89.7%, p = 1.0) and higher AHV assessability rate than PEI at PVP (96.8% vs. 80.2%, p < 0.001).

CONCLUSION

DLCT-VMI improved RAV assessments before AVS. Using VMI40 for PVP provided RAV depiction equivalent to PEI at LAP and superior AHV assessability to PEI at PVP, suggesting its potential as a surrogate for dedicated multiphase CT.

Для цитирования: Yoshida Ryuya, Nagayama Yasunori, Esaki Takumi, Matsumoto Taiga, Tamura Yoshitaka, Ishiuchi Soichiro, Inoue Taihei, Sakabe Daisuke, Igarashi Yasuaki, Kidoh Masafumi, Oda Seitaro, Nakaura Takeshi, Kiyosue Hiro, Hirai Toshinori. Dual-layer spectral detector CT for improved assessment of right adrenal vein in patients with primary aldosteronism.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05165-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.