Functional Gaps and Atrial Fibrosis as Predictors of Early Arrhythmia Recurrence After Robotic-Enhanced Hybrid Ablation for Persistent Atrial Fibrillation.

Celentano Eduardo, Cristiano Ernesto, Bertella Erika, Parrinello Matteo, Albano Giovanni, Ignatiuk Barbara, Renda Martina, Bia Elena, d'Amico Anthea, Rainone Raffaele, Graniero Ascanio, Giroletti Laura, Polini Laura, Gasparri Mario, Schena Stefano, Agnino Alfonso, De Groot Natasja M S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Robotic-enhanced hybrid ablation (RE-HA) is a promising strategy for persistent (PsAF) and long-standing persistent atrial fibrillation (LS-PsAF). The impact of post-epicardial conduction gaps and atrial fibrosis on early arrhythmia recurrence (EAR) is unclear.

OBJECTIVE

To assess whether conduction gaps and atrial fibrosis predict EAR within 3 months after the epicardial stage of RE-HA.

METHODS

Forty-two PsAF/LS-PsAF patients underwent RE-HA with left atrial appendage closure. High-density endocardial mapping at 3 months identified fixed (present in all maps) and functional (present in ≥1 but not all maps) conduction gaps. Atrial fibrosis was quantified by pre-procedural cardiac magnetic resonance (CMR).

RESULTS

Gaps were found in 18 patients (42.3%): functional in 10 (23.8%) and fixed in 13 (31.0%), with 5 (12%) showing both. EAR occurred in 12 patients (28.6%), AFL in 10/12 (83.3%). Gaps predicted AFL (OR 4.56; p = 0.003) and EAR (OR 3.50; p = 0.005). Left atrium LGE ≥ 10% independently predicted EAR (OR 7.50; p = 0.019) with no interaction with gap presence (p = 0.24). Total RF time was similar between groups despite more gaps in recurrence cases, reflecting procedural factors beyond gap count. Roof-line gaps predominated and colocalized with epicardial fat on CMR.

CONCLUSION

Delayed high-density mapping after RE-HA reveals fixed and functional conduction gaps, especially at the roof line, that-together with pre-ablation fibrosis-independently predict EAR. These findings highlight distinct anatomical and electrophysiological risk domains and support substrate assessment with targeted endocardial completion in a staged workflow.

Для цитирования: Celentano Eduardo, Cristiano Ernesto, Bertella Erika, Parrinello Matteo, Albano Giovanni, Ignatiuk Barbara, Renda Martina, Bia Elena, d'Amico Anthea, Rainone Raffaele, Graniero Ascanio, Giroletti Laura, Polini Laura, Gasparri Mario, Schena Stefano, Agnino Alfonso, De Groot Natasja M S. Functional Gaps and Atrial Fibrosis as Predictors of Early Arrhythmia Recurrence After Robotic-Enhanced Hybrid Ablation for Persistent Atrial Fibrillation.. Journal of cardiovascular electrophysiology. 2025. DOI: 10.1111/jce.70117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.