MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-021-08637-1

Медицинская библиотека · Surgical endoscopy · 2021

Utility of contrast-enhanced harmonic endoscopic ultrasonography for T-staging of patients with extrahepatic bile duct cancer.

Otsuka Yasuo, Kamata Ken, Hyodo Tomoko, Chikugo Takaaki, Hara Akane, Tanaka Hidekazu, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Minaga Kosuke, Yamao Kentaro, Takenaka Mamoru, Chiba Yasutaka, Watanabe Tomohiro, Nakai Takuya, Matsumoto Ippei, Takeyama Yoshifumi, Kudo Masatoshi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The value of contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS) for T-staging in patients with extrahepatic bile duct cancer was evaluated.

METHODS

This single-center, retrospective study included consecutive patients with extrahepatic bile duct cancer who underwent surgical resection after preoperative EUS, CH-EUS, and contrast-enhanced CT (CE-CT) examinations between June 2014 and August 2017. The capacity of these modalities for T-staging of extrahepatic bile duct cancer was evaluated by assessing invasion beyond the biliary wall into the surrounding tissue, gallbladder, liver, pancreas, duodenum, portal vein system (portal vein and/or superior mesenteric vein), inferior vena cava, and hepatic arteries (proper hepatic artery, right. and/or left. hepatic artery). Blind reading of EUS, CH-EUS, and CE-CT images was performed by two expert reviewers each.

RESULTS

38 patients were eligible for analysis, of which eight had perihilar bile duct cancer and 30 had distal bile duct cancer. Postoperative T-staging was T1 in 6, T2 in 16, and T3 in 16 cases. CH-EUS was superior to CE-CT for diagnosing invasion beyond the biliary wall into surrounding tissue (92.1% vs. 45.9%, P = 0.0002); the ability to detect invasion to other organs did not differ significantly between the two modalities. The accuracy of CH-EUS for T-staging of tumors was better than that of CE-CT (73.7% vs. 39.5%, P = 0.0059). CH-EUS tended to have a better accuracy than EUS for the diagnosis of invasion beyond the biliary wall into the surrounding tissue (92.1% vs. 78.9%, P = 0.074) and T-staging (73.7% vs. 60.5%, P = 0.074).

CONCLUSION

CH-EUS is useful for T-staging of extra hepatic bile duct cancer, especially in terms of invasion beyond the biliary wall into the surrounding tissue.

Для цитирования: Otsuka Yasuo, Kamata Ken, Hyodo Tomoko, Chikugo Takaaki, Hara Akane, Tanaka Hidekazu, Yoshikawa Tomoe, Ishikawa Rei, Okamoto Ayana, Yamazaki Tomohiro, Nakai Atsushi, Omoto Shunsuke, Minaga Kosuke, Yamao Kentaro, Takenaka Mamoru, Chiba Yasutaka, Watanabe Tomohiro, Nakai Takuya, Matsumoto Ippei, Takeyama Yoshifumi, Kudo Masatoshi. Utility of contrast-enhanced harmonic endoscopic ultrasonography for T-staging of patients with extrahepatic bile duct cancer.. Surgical endoscopy. 2021. DOI: 10.1007/s00464-021-08637-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.