MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2019-315227

Медицинская библиотека · Heart (British Cardiac Society) · 2019

Manganese-enhanced MRI of the myocardium.

Spath Nick B, Thompson Gerard, Baker Andrew H, Dweck Marc R, Newby David E, Semple Scott I K

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

Gadolinium-based contrast media are widely used in cardiovascular MRI to identify and to highlight the intravascular and extracellular space. After gadolinium, manganese has the second highest paramagnetic moment and was one of the first MRI contrast agents assessed in humans. Over the last 50 years, manganese-enhanced MRI (MEMRI) has emerged as a complementary approach enabling intracellular myocardial contrast imaging that can identify functional myocardium through its ability to act as a calcium analogue. Early progress was limited by its potential to cause myocardial depression. To overcome this problem, two clinical formulations of manganese were developed using either chelation (manganese dipyridoxyl diphosphate) or coadministration with a calcium compound (EVP1001-1, Eagle Vision Pharmaceuticals). Preclinical studies have demonstrated the efficacy of MEMRI in quantifying myocardial infarction and detecting myocardial viability as well as tracking altered contractility and calcium handling in cardiomyopathy. Recent clinical data suggest that MEMRI has exciting potential in the quantification of myocardial viability in ischaemic cardiomyopathy, the early detection of abnormalities in myocardial calcium handling, and ultimately, in the development of novel therapies for myocardial infarction or heart failure by actively quantifying viable myocardium. The stage is now set for wider clinical translational study of this novel and promising non-invasive imaging modality.

Для цитирования: Spath Nick B, Thompson Gerard, Baker Andrew H, Dweck Marc R, Newby David E, Semple Scott I K. Manganese-enhanced MRI of the myocardium.. Heart (British Cardiac Society). 2019. DOI: 10.1136/heartjnl-2019-315227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.