m+Medelevator.RU
← Поиск публикаций
Respiratory medicine and research · 2025

Chest mechanics after endoscopic lung volume reduction: Comparison between responders and non-responders based on dynamic hyperinflation.

Клиническое исследованиеСравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Taton Olivier, Perez-Bogerd Silvia, Van Muylem Alain, Gevenois Pierre Alain, Van Hove Olivier, Bondue Benjamin, Brenard Emmeline, Leduc Dimitri

Аннотация

BACKGROUND: Endobronchial lung volume reduction (ELVR) improves lung function, exercise capacity, and quality of life in case of severe emphysema. Nevertheless, not all patients are improved by ELVR including those with substantially decreased lung volume. We tested the hypothesis that unilateral volume loss could impact differently both responders and non-responders.

METHODS: A retrospective analysis was performed on 20 patients, classified as 13 responders and 7 non-responders based on inspiratory capacity increase ≥200 ml at isotime. We compared changes in lung volume, diaphragm shape and strength, mediastinal shift, lung function, exercise capacity, and quality of life before and three months after ELVR.

RESULTS: Compared to non-responders, responders showed a more improved diaphragm strength (4 vs. 2 cmH2O, p = 0.0318) and shape in both sides (non-treated side total area: +42 (7-54) cm2, p = 0.0079, non-treated side zone of apposition: +26 (18-52) cm2, p = 0.0270). Responders had a larger mediastinal shift than non-responders (13 vs. 3 degrees, p = 0.0039) with significant positive correlations between mediastinal shift and improvements in lung function (FEV1: r = 0.48, p = 0.0365), exercise capacity (6MWD: r = 0.78, p < 0.0001, inspiratory capacity: r = 0.48, p = 0.0365), and quality of life (CAT: r=-0.58, p = 0.0096).

CONCLUSIONS: Dynamic hyperinflation responders present a larger mediastinal shift than non-responders. This shift could be a marker of improved diaphragm shape and strength in both treated and non-treated sides.

CLINICAL TRIAL REGISTRATION: NCT05799352.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты