MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1552-6569.2007.00236.x

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2008

Contrast-enhanced transcranial color-coded duplex sonography criteria for basilar artery stenosis.

Tateishi Yohei, Iguchi Yasuyuki, Kimura Kazumi, Inoue Takeshi, Shibazaki Kensaku, Eguchi Katsumi

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: The aim of this study is to assess contrast-enhanced transcranial color-coded duplex sonography (CE-TCCS) diagnosis of basilar artery (BA) stenosis.

METHODS

CE-TCCS and cerebral angiography were performed in 120 consecutive patients. The patients were angiographically divided into five groups: (1) intracranial arteries (ICA) stenosis but no BA stenosis as intracranial stenosis (ICS) group, (2) both ICA and BA stenoses as internal carotid arteay and basilar arteay stenoses (IBS) group, (3) BA stenosis as basilar artery stenosis (BAS) group, (4) BA occlusion as basilar artery occlusion (BAO) group, and (5) no arterial lesions as Control group. We compared the peak systolic flow velocity (PSV) of BA using CE-TCCS.

RESULTS

PSV was highest in the BAS group (n= 9, 206.1 +/- 118.6 cm/sec), followed by the ICS (n= 27, 74.9 +/- 36.1 cm/sec) and Control (n= 70, 58.2 +/- 17.3 cm/sec) groups. IBS group had two patients (PSV: 102 cm/sec and 167 cm/sec). Sensitivity-specificity curve analysis revealed a cutoff PSV of 120 cm/sec to distinguish the BAS group from other groups, and then we calculated sensitivity of 100%, specificity of 95%, positive predictive value of 64%, negative predictive value of 100%, and accuracy of 95%.

CONCLUSION

Measurement of PSV of the BA using CE-TCCS is useful for the identification of BA stenosis.

Для цитирования: Tateishi Yohei, Iguchi Yasuyuki, Kimura Kazumi, Inoue Takeshi, Shibazaki Kensaku, Eguchi Katsumi. Contrast-enhanced transcranial color-coded duplex sonography criteria for basilar artery stenosis.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2008. DOI: 10.1111/j.1552-6569.2007.00236.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.