Paraprosthetic leak closure 28 years after mitral caged-ball Starr-Edwards implantation.

Antończyk Karolina, Paluszkiewicz Lech, Koertke Heinrich, Gummert Jan

Клинический случайСтатьяПеревод в очереди

Аннотация

In this case report, we present a patient 28 years after mitral valve replacement with the Starr-Edwards prosthesis complicated by periprosthetic leak with severe aortic stenosis and moderate tricuspid regurgitation. We successfully repaired the periprosthetic regurgitation in a patient with extensive mitral annular calcification, without replacement of the valve. No apparent structural deterioration on the caged-ball valve was found. Moreover, aortic valve replacement and tricuspid annuloplasty were performed. One month after reoperation, the patient remained stable with improved clinical status and without any evidence for further paravalvular leak.

Для цитирования: Antończyk Karolina, Paluszkiewicz Lech, Koertke Heinrich, Gummert Jan. Paraprosthetic leak closure 28 years after mitral caged-ball Starr-Edwards implantation.. Interactive cardiovascular and thoracic surgery. 2013. DOI: 10.1093/icvts/ivt174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.