von Stein Jennifer, von Stein Philipp, Stolz Lukas, Althoff Jan, Hasse Caroline, Rosch Sebastian, Rudolph Felix, Kirchner Johannes, Goebel Bjoern, Koell Benedikt, Rottbauer Wolfgang, Rassaf Tienush, Beucher Harald, Kraus Martin, Kassar Mohammad, Geisler Tobias, Rück Andreas, Ferreira-Martins Joao, Toggweiler Stefan, Sagmeister Paula, Westermann Dirk, Stocker Thomas J, Weckbach Ludwig T, Näbauer Michael, Dawkins Sam, Kister Tobias, Vorpahl Marc, Konstandin Mathias H, Luedike Peter, Kessler Mirjam, Iliadis Christos, Lauten Philipp, Besler Christian, Kalbacher Daniel, Friedrichs Kai, Gerçek Muhammed, Granada Juan F, Lurz Philipp, Hausleiter Jörg, Wild Mirjam G, Körber Maria I, PASTE Investigators

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transcatheter tricuspid valve (TV) interventions are an effective treatment option for patients with severe symptomatic tricuspid regurgitation (TR). TV transcatheter edge-to-edge repair (T-TEER) and transcatheter TV annuloplasty (TTVA) represent distinct repair strategies; however, comparative data remain limited.

OBJECTIVES

The objective of the study was to compare procedural and clinical outcomes after T-TEER and TTVA in patients with severe secondary TR.

METHODS

Consecutive T-TEER or TTVA-treated patients (2017-2024) were included. A 1:1 propensity-score matching was performed. Endpoints included residual TR ≤ 1+/≤2+, a ≥2-grade reduction, procedural complications, symptomatic improvement, reinterventions, and the composite of all-cause mortality or first heart failure hospitalization within 1 year.

RESULTS

Among 1,122 patients (882 T-TEER; 240 TTVA), 111 well-balanced matched pairs were identified. At discharge, T-TEER achieved higher rates of residual TR ≤ 1+ (50.0% vs 34.2%) and ≤2+ (87.7% vs 67.6%; all P < 0.05) compared with TTVA, whereas a ≥2-grade reduction was comparable. Procedural complications were less frequent with T-TEER (any complication: 4.5% vs 27.0% for T-TEER vs TTVA; P < 0.001). Symptomatic improvement and reintervention rates within 1 year were similar between groups. Freedom from the composite endpoint of all-cause mortality or first heart failure hospitalization at 1-year was 75.0% (95% CI: 66.8-84.1) after T-TEER and 79.8% (95% CI: 72.4-87.9) after TTVA (P = 0.408).

CONCLUSIONS

In patients with severe secondary TR and sufficient clinical and anatomical overlap for matched comparison, T-TEER showed a more favorable safety profile and more effective, durable TR reduction, whereas early clinical outcomes at 1 year were comparable after adjustment for baseline differences, highlighting the need for longer-term evaluation.

Для цитирования: von Stein Jennifer, von Stein Philipp, Stolz Lukas, Althoff Jan, Hasse Caroline, Rosch Sebastian, Rudolph Felix, Kirchner Johannes, Goebel Bjoern, Koell Benedikt, Rottbauer Wolfgang, Rassaf Tienush, Beucher Harald, Kraus Martin, Kassar Mohammad, Geisler Tobias, Rück Andreas, Ferreira-Martins Joao, Toggweiler Stefan, Sagmeister Paula, Westermann Dirk, Stocker Thomas J, Weckbach Ludwig T, Näbauer Michael, Dawkins Sam, Kister Tobias, Vorpahl Marc, Konstandin Mathias H, Luedike Peter, Kessler Mirjam, Iliadis Christos, Lauten Philipp, Besler Christian, Kalbacher Daniel, Friedrichs Kai, Gerçek Muhammed, Granada Juan F, Lurz Philipp, Hausleiter Jörg, Wild Mirjam G, Körber Maria I, PASTE Investigators. Transcatheter Tricuspid Valve Annuloplasty vs Edge-to-Edge Repair: A Propensity-Matched Multicenter Comparative Analysis.. JACC. Advances. 2026. DOI: 10.1016/j.jacadv.2026.103033.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.