MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12957-025-03898-9

Медицинская библиотека · World journal of surgical oncology · 2026

Diagnostic accuracy of computer-aided detection for colorectal polyps of any size, ≤ 5 mm, and 6-9 mm: a meta-analysis.

Chen Wen, Li Simeng, Wu Zhenheng, Tan Haifen, Yu Fuqian, Wang Dongmei, Lin Xiaodan, Chen Zhigang

СтатьяМетаанализПеревод в очереди

Аннотация

BACKGROUND

Although computer-aided detection (CAD) is often used for medical diagnostic purposes, its diagnostic effectiveness in colorectal polyps (CPs) remains uncertain.

OBJECTIVE

To summarize the diagnostic accuracy of CAD in diagnosing CPs, and provide a specific theoretical basis for clinical practice.

METHODS

From database creation to August 1st 2024, we conducted a comprehensive search of PubMed, Embase, Web of Science (WoS), Scopus, Wanfang, Cochrane Library, and the China National Knowledge Infrastructure (CNKI). The pooled sensitivity, specificity, area under the curve (AUC), diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and Fagan plot analysis were employed to evaluate the overall performance of CAD tests. Furthermore, we assessed publication bias using Deeks' funnel plot asymmetry test.

RESULTS

The aggregated diagnostic data from 19 studies (any size), 12 studies (≤ 5 mm polyps) and 2 studies (6-9 mm polyps) were as follows: The sensitivity for polyps of any size, ≤ 5 mm, and 6-9 mm was 0.94 (95% CI, 0.92-0.96), 0.93 (95% CI, 0.89-0.95) and 0.95 (95% CI, 0.92-0.97), respectively. The specificity was 0.91 (95% CI, 0.86-0.95), 0.90 (95% CI, 0.87-0.93) and 0.90 (95% CI, 0.88-0.92), respectively. The AUC was 0.97 (95% CI, 0.96-0.99), 0.96 (95% CI, 0.94-0.98), and 0.92 (95% CI, 0.89-0.94), respectively. Deeks' funnel plot showed that publication bias was not statistically significant in the diagnosis of polyps of any size and ≤ 5 mm CPs (P > 0.05).

CONCLUSION

In summary, CAD is accurate for all types of CPs. Specifically, for polyps of any size and those ≤ 5 mm, CAD was more sensitive and specific for CPs of any size.

Для цитирования: Chen Wen, Li Simeng, Wu Zhenheng, Tan Haifen, Yu Fuqian, Wang Dongmei, Lin Xiaodan, Chen Zhigang. Diagnostic accuracy of computer-aided detection for colorectal polyps of any size, ≤ 5 mm, and 6-9 mm: a meta-analysis.. World journal of surgical oncology. 2026. DOI: 10.1186/s12957-025-03898-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.