AIMS: The relationship between local unipolar voltage (UV) in the pulmonary vein (PV)-ostia and left atrial wall thickness (LAWT) and the utility of these parameters as indices of outcome after atrial fibrillation (AF) ablation remain unclear.

METHODS AND

RESULTS

Two-hundred seventy-two AF patients who underwent AF ablation were enrolled. Unipolar voltage of PV-ostia was measured using a CARTO system, and LAWT was measured using computed tomography. The primary endpoint was atrial tachyarrhythmia (ATA) recurrence including AF. The ATA recurrence was documented in 74 patients (ATA-Rec group). The UV and LAWT of the bilateral superior PV roof to posterior and around the right-inferior PV in the ATA-Rec group were significantly greater than in patients without ATA recurrence (ATA-Free group) (P < 0.001). The UV had a strong positive correlation with LAWT (R2 = 0.446, P < 0.001). The UV 2.7 mV and the corresponding LAWT 1.6 mm were determined as the cut-off values for ATA recurrence (P < 0.001, respectively). Multisite LA high UV (HUV, ≥4 areas of >2.7 mV) or multisite LA wall thickening (≥5 areas of >1.6 mm), defined as LA hypertrophy (LAH), was related to higher ATA recurrence. Among 92 LAH patients, 66 had HUV (LAH-HUV) and the remaining 26 had low UV (LAH-LUV), characterized by history of non-paroxysmal AF and heart failure, reduced LV ejection fraction, or enlarged LA. In addition, LAH-LUV showed the worst ablation outcome, followed by LAH-HUV and No LAH (log-rank P < 0.001).

CONCLUSION

Combining UV and LAWT enables us to stratify recurrence risk and suggest a tailored ablation strategy according to LA tissue properties.

Для цитирования: Kamioka Masashi, Makimoto Hisaki, Watanabe Tomonori, Watanabe Hiroaki, Okuyama Takafumi, Kaneshiro Takashi, Hijioka Naoko, Yokota Ayako, Komori Takahiro, Kabutoya Tomoyuki, Imai Yasushi, Kario Kazuomi. Unipolar-voltage-based evaluation of left atrial tissue properties and ablation outcome in patients with atrial fibrillation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2023. DOI: 10.1093/europace/euad240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.