MedElevator Войти в исследования
← Поиск публикаций

DOI 10.70352/scrj.cr.25-0823

Медицинская библиотека · Surgical case reports · 2026

Anomalous Systemic Arterial Supply to the Basal Segments with an Aneurysmal Aberrant Artery Showing Advanced Wall Fragility: A Case Report and Literature Review.

Yorimori Shun, Suzuki Shigeki, Shida Kenta, Sugino Kosuke, Suzuki Takahiro, Okubo Yu, Haida Hirofumi, Masai Kyohei, Kaseda Kaoru, Kurebayashi Yutaka, Hashizume Kenichi, Shimizu Hideyuki, Asakura Keisuke

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Anomalous systemic arterial supply to the basal segments (ASABS) is a rare congenital pulmonary anomaly. Considering the associated complications of pulmonary hypertension or hemoptysis, surgical lung resection is recommended. However, there is a lack of standardized surgical management guidelines. We report a case of ASABS with an aneurysmal aberrant artery, in which imaging findings suggested an increased risk of rupture. Thoracic endovascular aortic repair (TEVAR) was first performed to achieve inflow control; this strategy provided a secure setting for subsequent pulmonary resections.

CASE PRESENTATION: A 56-year-old woman presented with an abnormal chest shadow. Contrast-enhanced chest CT revealed an aberrant artery arising from the descending aorta supplying the left basal segment with an irregular aneurysm measuring 33 mm. Non-contrast chest CT demonstrated intraluminal hyperattenuation consistent with acute thrombosis, raising concerns regarding an increased risk of rupture. The absence of a normal pulmonary arterial supply to the basal segment and normal bronchial and pulmonary venous anatomy confirmed the diagnosis of ASABS. Given the radiologic findings suggestive of an increased risk of rupture of an aberrant artery, preoperative TEVAR was performed to control the inflow to the aberrant artery. After 18 days, video-assisted left lower lobectomy with division of the aberrant artery was performed safely. The postoperative course was uneventful, and the patient was discharged 10 days after surgery. Pathology revealed disruption of the elastic fibers and thinning of the media, supporting aneurysmal degeneration at the risk of rupture. Contrast-enhanced CT performed 6 months after surgery confirmed the absence of an endoleak or stump aneurysm.

CONCLUSIONS

The TEVAR-first approach for inflow control enabled safe pulmonary resection in ASABS with an aneurysmal aberrant artery. To the best of our knowledge, this is the first reported case for this condition where histopathological findings suggested an increased risk of rupture. Further investigation is needed to determine which patients benefit the most from this strategy and to understand the long-term outcomes.

Для цитирования: Yorimori Shun, Suzuki Shigeki, Shida Kenta, Sugino Kosuke, Suzuki Takahiro, Okubo Yu, Haida Hirofumi, Masai Kyohei, Kaseda Kaoru, Kurebayashi Yutaka, Hashizume Kenichi, Shimizu Hideyuki, Asakura Keisuke. Anomalous Systemic Arterial Supply to the Basal Segments with an Aneurysmal Aberrant Artery Showing Advanced Wall Fragility: A Case Report and Literature Review.. Surgical case reports. 2026. DOI: 10.70352/scrj.cr.25-0823.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.