Feasibility study of hand-carried ultrasound-guided retrievable inferior vena cava filter placement.

Zhu Hang, Du Wen-Juan, Wang Xiao-Hua, Yang Yang, Dekyi, Chen Yun-Dai, Zhao Jing

СтатьяПеревод в очереди

Аннотация

BACKGROUND

With the development of ultrasonic diagnostic techniques in recent years, ultrasound-guided placement of inferior vena cava (IVC) filters has been widely used in clinics, and satisfactory results have been achieved. Our study aims to observe the accuracy of hand-carried ultrasound-guided retrievable vena cava filter placement, evaluate the feasibility and safety of this new method, and provide a scientific and effective interventional method and clinical data to prevent acute pulmonary embolism (PE) after battle injury of limbs.

METHODS

Two hundred patients with post-traumatic thrombosis of the extremities were enrolled. The renal vein was located under the guidance of hand-carried ultrasound. The retrievable filter was fixed 1-2 cm below the opening of the renal vein. The self-expanding filter was used after the filter's position was confirmed by injecting the contrast agent under the digital subtraction angiography (DSA) fluoroscopy.

RESULTS

All the 200 patients underwent the operation successfully. The position of the hand-carried ultrasound localizer was consistent with the DSA localizer. All the filters were expanded smoothly. No complications related to the operation occurred.

CONCLUSIONS

The study concluded that the hand-carried ultrasound-guided retrievable vena cava filter placement has a high success rate and can prevent acute PE after limbs' battle injury.

Для цитирования: Zhu Hang, Du Wen-Juan, Wang Xiao-Hua, Yang Yang, Dekyi, Chen Yun-Dai, Zhao Jing. Feasibility study of hand-carried ultrasound-guided retrievable inferior vena cava filter placement.. Annals of translational medicine. 2021. DOI: 10.21037/atm-21-1290.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.