BACKGROUND

In repaired tetralogy of Fallot (rTOF), abnormal left ventricular (LV) rotational mechanics are associated with adverse clinical outcomes. We performed a comprehensive analysis of LV rotational mechanics in rTOF patients using cardiac magnetic resonance (CMR) prior to and following surgical pulmonary valve replacement (PVR).

METHODS

In this single center retrospective study, we identified rTOF patients who (1) had both a CMR ≤ 1 year before PVR and ≤ 5 years after PVR, (2) had no other intervening procedure between CMRs, (3) had a body surface area > 1.0 m2 at CMR, and (4) had images suitable for feature tracking analysis. These subjects were matched to healthy age- and sex-matched control subjects. CMR feature tracking analysis was performed on a ventricular short-axis stack of balanced steady-state free precession images. Measurements included LV basal and apical rotation, twist, torsion, peak systolic rates of rotation and torsion, and timing of events. Associations with LV torsion were assessed.

RESULTS

A total of 60 rTOF patients (23.6 ± 7.9 years, 52% male) and 30 healthy control subjects (20.8 ± 3.1 years, 50% male) were included. Compared with healthy controls, rTOF patients had lower apical and basal rotation, twist, torsion, and systolic rotation rates, and these parameters peaked earlier in systole. The only parameters that were correlated with LV torsion were right ventricular (RV) end-systolic volume (r = - 0.28, p = 0.029) and RV ejection fraction (r = 0.26, p = 0.044). At a median of 1.0 year (IQR 0.5-1.7) following PVR, there was no significant change in LV rotational parameters versus pre-PVR despite reductions in RV volumes, RV mass, pulmonary regurgitation, and RV outflow tract obstruction.

CONCLUSION

In this comprehensive study of CMR-derived LV rotational mechanics in rTOF patients, rotation, twist, and torsion were diminished compared to controls and did not improve at a median of 1 year after PVR despite favorable RV remodeling.

Для цитирования: Harrington Jamie K, Ghelani Sunil, Thatte Nikhil, Valente Anne Marie, Geva Tal, Graf Julia A, Lu Minmin, Sleeper Lynn A, Powell Andrew J. Impact of pulmonary valve replacement on left ventricular rotational mechanics in repaired tetralogy of Fallot.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2021. DOI: 10.1186/s12968-021-00750-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.