MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-025-12154-3

Медицинская библиотека · European radiology · 2025

Deep endometriosis: evaluation of ENZIAN and #ENZIAN classification systems by MRI compared with surgery-a meta-analysis.

Mohamed Yusra, Kol Sabrine Q, Stoker Jaap, Bipat Shandra

СтатьяМетаанализСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To assess the reproducibility and the diagnostic accuracy of MRI for the assessment of (#)ENZIAN classification in patients with deep endometriosis by means of a meta-analysis.

MATERIALS AND

METHODS

MEDLINE and EMBASE databases were searched for relevant articles from January 1, 2005, to January 1, 2025. Data on MRI reproducibility (interobserver/intraobserver kappa) were extracted for P (peritoneum), O (ovary), T (tubo-ovarian condition), A (vagina/rectovaginal space), B (utero-sacral ligaments), C (rectum/sigmoid colon), FA (F adenomyosis), FB (F bladder), FU (F ureter), FI (F intestinum), and FO (F other). Pooled sensitivity, specificity, PPV, and NPV were calculated for each compartment.

RESULTS

Twelve articles (1024 patients) were included, of which 7 used ENZIAN and 5 used #ENZIAN. MRI-based (#)ENZIAN showed high reliability for O, A, B, and C, with substantial or excellent agreement in most studies. MRI-based (#)ENZIAN showed high diagnostic values for O, T, A, B, and C. Sensitivity and specificity for O were 97.5% and 96.4% and for T, 94.1% and 89.1%, respectively. Sensitivity values for A, B, and C were slightly lower, but remained high at 76.1%, 83.4%, and 79.1% respectively, and specificity values were high at 92.4%, 87.8%, and 94.8%. Sensitivity values for FA, FB, and FI were low, with values of 64.6%, 56.9%, and 66.8%. Data for P, FU, and FO were insufficient and could not be pooled.

CONCLUSION

MRI-based (#)ENZIAN showed high reliability for compartments O, T, A, B, and C. Data for other compartments were either insufficient or the diagnostic accuracy was low.

KEY POINTS: Question What is the diagnostic value of MRI in the assessment of (#) ENZIAN classification in patients with deep endometriosis? Findings MRI-based(#)ENZIAN showed high diagnostic values for compartments O, T, A, B, and C. Data on the remaining compartments were insufficient, or the diagnostic accuracy was low. Clinical relevance MRI-based (#) ENZIAN can be used for assessing endometriosis located at the ovaries, tubal ovarian condition, vaginal-rectovaginal space, utero-sacral ligaments, and rectosigmoid. For other compartments, more data are needed and clear definitions might also improve the role of MRI.

Для цитирования: Mohamed Yusra, Kol Sabrine Q, Stoker Jaap, Bipat Shandra. Deep endometriosis: evaluation of ENZIAN and #ENZIAN classification systems by MRI compared with surgery-a meta-analysis.. European radiology. 2025. DOI: 10.1007/s00330-025-12154-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.