Internal fistula stenosis with true pseudoaneurysm formation in a patient on maintenance hemodialysis: A case report.

Tong Xiaoya, Ran Yan, Da Jingjing, Hu Ying, Yuan Jing, Rui Yan

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Arteriovenous fistula stenosis can directly lead to the formation of autologous arteriovenous fistula aneurysms (AVFAs), but the coexistence of true and pseudoaneurysms is relatively rare. The coexistence of true and pseudoaneurysms increases the risk of rupture of the arteriovenous fistula and complicates subsequent surgical intervention, potentially posing a threat to the patient's life, and thus requires significant attention.

CASE PRESENTATION: The patient presented with arteriovenous fistula (AVF) after hemodialysis 6 years ago. 2 years ago, the patient presented with a mass that had formed near the left forearm arteriovenous fistula and gradually increased in size. Preoperatively, the AVF stenosis was identified as the cause of the mass formation, and the patient was operated on. First, the blood flow was controlled to reduce the pressure at the aneurysm, and then the incision was enlarged to separate the AVF anastomosis from the mass area. The stenotic segment of the true and pseudo aneurysms and cephalic vein was removed and the over-dilated proximal cephalic vein was locally narrowed and subsequently anastomosed with the proximal radial artery to create AVF. The patient was dialyzed with an internal fistula the next day and showed no clinical manifestations related to end-limb ischemia.

CONCLUSION

We removed a true pseudoaneurysm in AVF and secured the patient's vascular access. This report provides an effective strategy to manage this condition.

Для цитирования: Tong Xiaoya, Ran Yan, Da Jingjing, Hu Ying, Yuan Jing, Rui Yan. Internal fistula stenosis with true pseudoaneurysm formation in a patient on maintenance hemodialysis: A case report.. Medicine. 2024. DOI: 10.1097/md.0000000000038111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.