MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.msec.2019.03.110

Медицинская библиотека · Materials science & engineering. C, Materials for biological applications · 2019

TEMPO oxidized nano-cellulose containing thermo-responsive injectable hydrogel for post-surgical peritoneal tissue adhesion prevention.

Sultana Tamanna, Van Hai Ho, Abueva Celine, Kang Hoe Jin, Lee Sun-Young, Lee Byong-Taek

СтатьяПеревод в очереди

Аннотация

The objective of this study was to present an effective injectable adhesion barrier comprised of TEMPO-oxidized cellulose nanofiber (TOCN), methyl cellulose, carboxymethyl cellulose, and polyethylene glycol. Hydrogels with different concentrations (0.2, 0.5, 0.8, 1% w/v) of bio compatible TOCN were investigated to determine their abilities to prevent post-surgical peritoneal adhesion using a rat cecal wall abrasion model. Sol-gel transition at body temperature (37 °C) was optimized by adjusting concentration of sodium ions (Na+), with a gelation time of 45 ± 7 s. These TOCN containing hydrogels showed non cytotoxicity to rat bone marrow mesenchymal stem cells (RBMSCs) and L929 fibroblast cells as cell models during in vitro assessment. Degradation studies revealed that, TOCN concentration in hydrogel was inversely proportional to hydrolytic degradation rate. From in vivo evaluations, TOCN 0.2 hydrogel significantly reduced peritoneal adhesion in rat (n = 8) compared to untreated controls based on gross observation, histological analysis, and expression analysis of marker proteins. By taking advantages of thermo gelling, high stability, non-invasive way of application and rapid recovery potential, TOCN containing bio compatible hydrogel could be used as a cost-effective barrier to efficiently inhibit post-surgical peritoneal adhesions.

Для цитирования: Sultana Tamanna, Van Hai Ho, Abueva Celine, Kang Hoe Jin, Lee Sun-Young, Lee Byong-Taek. TEMPO oxidized nano-cellulose containing thermo-responsive injectable hydrogel for post-surgical peritoneal tissue adhesion prevention.. Materials science & engineering. C, Materials for biological applications. 2019. DOI: 10.1016/j.msec.2019.03.110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.