Polymorphic Ventricular Tachycardia and Torsades in Methadone Therapy Captured by Loop Recorder.

Ganthan Resha Reya, Elcicek Ahmed, Fahed Joud, Isber Rayna, Isber Nidal

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Methadone is associated with QT prolongation and risk of torsades de pointes, particularly at higher doses, and management becomes challenging when the precipitating factor cannot be eliminated.

CASE SUMMARY: A 56-year-old man on high-dose methadone with an implantable loop recorder experienced 3 episodes of polymorphic ventricular tachycardia and ventricular fibrillation, including a prolonged 94-second syncopal event. Device electrograms demonstrated pause-dependent initiation with short-long-short sequences and marked QT prolongation preceding arrhythmia onset. Despite limited follow-up, he ultimately agreed to wearable cardioverter-defibrillator therapy and subsequent implantable cardioverter-defibrillator (ICD) placement for secondary prevention.

DISCUSSION: This case highlights methadone-associated malignant ventricular arrhythmias, the importance of continuous rhythm monitoring, and the role of ICD insertion when the offending agent cannot be safely withdrawn.

TAKE-HOME MESSAGE: In high-risk patients with recurrent ventricular arrhythmias on methadone, individualized monitoring and ICD therapy may be warranted.

Для цитирования: Ganthan Resha Reya, Elcicek Ahmed, Fahed Joud, Isber Rayna, Isber Nidal. Polymorphic Ventricular Tachycardia and Torsades in Methadone Therapy Captured by Loop Recorder.. JACC. Case reports. 2026. DOI: 10.1016/j.jaccas.2026.108796.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.