MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/cnm.70158

Медицинская библиотека · International journal for numerical methods in biomedical engineering · 2026

Computational Hemoacoustic Investigation for Phonoangiography-Based Rupture Prediction in Compliant Fusiform Abdominal Aortic Aneurysm.

Morab Sumant R, Murallidharan Janani S, Sharma Atul

СтатьяПеревод в очереди

Аннотация

For sound signal-based diagnosis and rupture prediction of abdominal aortic aneurysms (AAA), this study performs a physiological fluid flexible-structure acoustic interaction (FfSAI) analysis for pulsatile blood-flow using an in-house solver. The presence of murmurs is computationally presented for the first time using a qualitative indicator of the acoustic signal. A pulsatile Newtonian blood-flow at the inlet, with Womersley number Wo $$ Wo $$  = 16.5, is considered. For a fusiform (axisymmetric) AAA, a parametric FfSAI study is presented with various height ( H $$ H $$ ) to diameter ( D $$ D $$ ) ratios H / D $$ H/D $$  = 0.3, 0.5, 0.7, 1.0, and 1.2, and width ( W $$ W $$ ) to diameter ( D $$ D $$ ) ratios W / D $$ W/D $$  = 0.5 and 1.0. Vertical skin-surface velocity ( u r ' $$ {u}_r^{\prime } $$ ) and rupture potential index ( RPI $$ \mathrm{RPI} $$ ) are calculated for different configurations. A significant 71% increase in cutoff frequencies of skin-surface acoustic velocity u r ' $$ {u}_r^{\prime } $$ is found with the variation of H / D $$ H/D $$ from 0.3 to 1.2-indicating phonoangiography-based diagnosis as well as distinction of aneurysm levels. The proposed CFD-based flow-visualization indicates a vortex impingement on the aneurysm wall as the primary cause of high cutoff frequencies in the acoustic spectrum. A correlation is proposed to calculate rupture-risk through frequency data based on RPI $$ \mathrm{RPI} $$ and u r ' $$ {u}_r^{\prime } $$ spectrum. The decibel values predicted by neglecting structural flexibility over-predict the bulge level ( H / D ≥ $$ H/D\ge $$ 1)-emphasizing the importance of arterial compliance in a computational study. This work establishes the efficacy of phonoangiography-based diagnosis in assisting medical practitioners with treatment planning and underscores the necessity of using an elastic model for structure.

Для цитирования: Morab Sumant R, Murallidharan Janani S, Sharma Atul. Computational Hemoacoustic Investigation for Phonoangiography-Based Rupture Prediction in Compliant Fusiform Abdominal Aortic Aneurysm.. International journal for numerical methods in biomedical engineering. 2026. DOI: 10.1002/cnm.70158.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.