DOI 10.1016/j.wneu.2019.10.008
Endovascular Treatment of a Traumatic Middle Cerebral Artery Pseudoaneurysm with the Pipeline Flex Embolization Device.
Аннотация
OBJECTIVE
Traumatic pseudoaneurysms of the proximal middle cerebral artery (MCA) segments are challenging to treat. We describe the management of traumatic internal carotid artery and MCA pseudoaneurysms with flow diversion.
CASE DESCRIPTION: A 19-year-old man had sustained a gunshot wound to the head. Delayed digital subtraction angiography showed de novo formation of the left internal carotid artery ophthalmic segment and left MCA M2 segment pseudoaneurysms. We had initially performed coil embolization of the left MCA pseudoaneurysm. However, it had recurred 2 weeks later. We treated both pseudoaneurysms with flow diversion using the Pipeline Flex embolization device. The patient has continued with dual antiplatelet therapy of aspirin and ticagrelor. Follow-up digital subtraction angiography at 6 months showed complete obliteration of both pseudoaneurysms with patent parent vessels. The patient remained neurologically intact.
CONCLUSIONS
Flow diversion can be an efficacious treatment of traumatic MCA pseudoaneurysms in appropriately selected cases. The risks versus benefits of dual antiplatelet therapy must be weighed in trauma settings.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.