MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/17482941.2017.1293830

Медицинская библиотека · Acute cardiac care · 2017

Intrapulmonary artery balloon pulsation improves circulatory function after acute myocardial infarction in pigs.

Ouardani Rahma, Magkoutis Nikos, Bonnin Philippe, Kang Chantal, Kedra Antoni W, Sideris Georgios, Bonneau Michel, Voicu Sebastian

СтатьяПеревод в очереди

Аннотация

AIM: To examine whether pulmonary artery balloon pulsation (PABP) could improve circulatory function in acute myocardial infarction (AMI) in pigs.

METHODS/

RESULTS

Ten downsize pigs were sedated and ventilated. AMI was induced by inserting a plug into the left anterior descending artery. A pulsation balloon was placed in the pulmonary artery in all animals. In the treatment group (TG), pulsations began when life-threatening arrhythmia or > 30% drop in mean blood pressure (MBP) or > 40% decrease in cardiac output compared to baseline occurred. Pulsation rate was 120/min, independent of the heartbeat, maintained for 10 min. The control group (CG) received no pulsation. In the TG (n = 5), mean BP after the AMI improved by 7 ± 12 mmHg after 150 min while in the CG, MBP decreased by 17 ± 25 mmHg, P < 0.05; coronary perfusion pressure improved by 8 ± 7 mmHg in the TG but decreased by 15 ± 12 in the CG (P < 0.05). In the CG, cardiac output did not change but in the TG it improved from 3.5 ± 0.9 after the AMI to 4.2 ± 1.1 l/min 150 min after AMI (P < 0.05). The TG required 1.8 ± 0.4 electric shocks for ventricular fibrillation versus 0.8 ± 0.4 in the pulsation group (P < 0.05).

CONCLUSION

PABP could be useful in the management of AMI due to improved mean arterial BP, coronary perfusion pressure, cardiac output and electrical stability. The mechanism of this effect remains to be determined.

Для цитирования: Ouardani Rahma, Magkoutis Nikos, Bonnin Philippe, Kang Chantal, Kedra Antoni W, Sideris Georgios, Bonneau Michel, Voicu Sebastian. Intrapulmonary artery balloon pulsation improves circulatory function after acute myocardial infarction in pigs.. Acute cardiac care. 2017. DOI: 10.1080/17482941.2017.1293830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.