Reduced Receipt of Dedicated Computed Tomography With Implementation of a New Temporal Bone Fracture Protocol.

Patel Aneesh A, Tandler Charles, Sakai Osamu, Weber Peter C

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Temporal bone computed tomography (TBCT) is used to evaluate temporal bone fractures, but on average, it can result in additional radiation exposure and extra cost without clear clinical benefit. This study aimed to determine whether a new protocol could decrease the receipt of dedicated TBCT without impacting temporal bone fracture management.

METHODS

A retrospective review of patients sustaining temporal bone fractures at a level I trauma center from January 1, 2019 to January 1, 2024 was completed before and after the implementation of a protocol to reconstruct 0.625 mm thick images at 0.3 mm spacing TBCT from existing CT head instead of the immediate performance of TBCT (IRB H-44161). Primary outcomes included the incidence of dedicated TBCT and treatment and the incidence of otologic complications.

RESULTS

During the study period, 17 of 69 patients who sustained temporal bone fractures were evaluated after protocol implementation. After implementation, patients had significantly lower odds of obtaining dedicated TBCT (OR = 0.077, 95% CI = 0.0158, 0.3726, P = .0002) with no significant differences in medical (P = .5385) management. Otic capsule involvement (P = .3110) and otologic complications, including cerebrospinal fluid leak, facial nerve paresis, or hearing loss (P = 1), also did not differ significantly. Avoidance of dedicated TBCT reduced the effective radiation dose by 1.1 mSv.

CONCLUSION

A protocol to reconstruct TBCT from previously obtained head CT scans has reduced the receipt of dedicated TBCT without differences in management or complication, reducing radiation exposure and decreasing healthcare costs.

Для цитирования: Patel Aneesh A, Tandler Charles, Sakai Osamu, Weber Peter C. Reduced Receipt of Dedicated Computed Tomography With Implementation of a New Temporal Bone Fracture Protocol.. The Annals of otology, rhinology, and laryngology. 2025. DOI: 10.1177/00034894251347106.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.