MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00540-016-2163-8

Медицинская библиотека · Journal of anesthesia · 2016

Management of three cardiogenic pulmonary edemas occurring in a patient scheduled for left ventricular assist device implantation: indicators for determining left ventricular assist device pump speed.

Toyama Hiroaki, Takei Yusuke, Saito Kazutomo, Ota Takahisa, Kurotaki Kenji, Ejima Yutaka, Matsuura Takeshi, Akiyama Masatoshi, Saiki Yoshikatsu, Yamauchi Masanori

Клинический случайСтатьяПеревод в очереди

Аннотация

A male patient with Marfan syndrome underwent aortic root replacement and developed left ventricular (LV) failure. Four years later, he underwent aortic arch and aortic valve replacement. Thereafter, his LV failure progressed, and cardiogenic pulmonary edema (CPE) appeared, which we treated with extracorporeal LV assist device (LVAD) placement. Three months later, the patient developed aspiration pneumonia, which caused hyperdynamic right ventricle (RV) and CPE. We treated by changing his pneumatic LVAD to a high-flow centrifugal pump. A month later, he underwent thoracoabdominal aortic replacement. After four weeks, he developed septic thrombosis and LVAD failure, which caused CPE. We treated with LVAD circuit replacement and an additional membrane oxygenator. Four months later, he underwent DuraHeart(®) implantation. During this course, pulmonary artery wedge pressure (PAWP) varied markedly. Additionally, systolic pulmonary artery pressure (sPAP), left atrial diameter (LAD), RV end-diastolic diameter (RVEDD) and estimated RV systolic pressure (esRVP) changed with PAWP changes. In this patient, LV failure and hyperdynamic RV caused the CPEs, which we treated by adjusting the LVAD output to the RV output. Determining LVAD output, RV function and LV end-diastolic diameter are typically referred, and PAWP, LAD, RVEDD, and sPAP could be also referred.

Для цитирования: Toyama Hiroaki, Takei Yusuke, Saito Kazutomo, Ota Takahisa, Kurotaki Kenji, Ejima Yutaka, Matsuura Takeshi, Akiyama Masatoshi, Saiki Yoshikatsu, Yamauchi Masanori. Management of three cardiogenic pulmonary edemas occurring in a patient scheduled for left ventricular assist device implantation: indicators for determining left ventricular assist device pump speed.. Journal of anesthesia. 2016. DOI: 10.1007/s00540-016-2163-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.