Hand-held dynamometry reliability in persons with neuropathic weakness.

Kilmer D D, McCrory M A, Wright N C, Rosko R A, Kim H R, Aitkens S G

СтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine test-retest reliability of hand-held dynamometry (HHD) in measuring strength of persons with neuropathic weakness.

DESIGN

Intratester and intertester reliability of HHD-measured strength over a 7- to 10-day period. In addition, HHD knee strength was compared with criterion standard of fixed dynamometry (FD).

SETTING

Human performance laboratory of a university.

PARTICIPANTS

Convenience sample of ambulatory outpatients with Hereditary Motor and Sensory Neuropathy, Type I (HMSN) (n = 10) and able-bodied controls (CTL) (n = 11).

MAIN OUTCOME MEASURE: Maximal isometric torque.

RESULTS

Intratester intraclass correlation coefficients (ICCs) were high, generally ranging from .82 to .96 for HHD- and FD-measured strength for both HMSN and CTL groups. There were no significant differences between sessions for HHD-measured strength, while FD-measured strength was only significantly different for knee extension (p < .01). Intertester reliability was generally good for both HHD- and FD-measured strength, with ICCs ranging from .72 to .97 for HMSN and CTL groups. Exceptions were knee extensors and ankle dorsiflexors for the CTL group. Knee extensor strength was significantly lower measured by HHD compared with FD (p < .01), but knee flexor strength was similar for the two methods.

CONCLUSION

HHD appears to be a reliable method to measure maximal isometric strength in persons with neurogenic weakness, and may be useful to quickly and objectively evaluate strength in the clinical setting.

Для цитирования: Kilmer D D, McCrory M A, Wright N C, Rosko R A, Kim H R, Aitkens S G. Hand-held dynamometry reliability in persons with neuropathic weakness.. Archives of physical medicine and rehabilitation. 1997. DOI: 10.1016/s0003-9993(97)90311-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.