DOI 10.1016/j.jcmg.2017.06.022

Медицинская библиотека · JACC. Cardiovascular imaging · 2017

Early Prosthetic Valve Dysfunction Due to Bioprosthetic Valve Thrombosis: The Role of Echocardiography.

Egbe Alexander, Pislaru Sorin V, Ali Mahmoud A, Khan Arooj R, Boler Amber N, Schaff Hartzell V, Akintoye Emmanuel, Connolly Heidi M, Nkomo Vuyisile T, Pellikka Patricia A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

The purpose of this study was to review the institutional practice of surveillance transthoracic echocardiography (TTE) for diagnosing early prosthetic valve dysfunction (PVD).

BACKGROUND

Bioprosthetic valve thrombosis (BPVT) is an important cause of PVD, and guidelines do not recommend routine TTE during the first 5 years after valve implantation.

METHODS

The authors performed a retrospective case-control study of all suspected (imaging diagnosis) or confirmed (histopathological diagnosis) cases of BPVT from January 1997 through December 2016. Patients were matched 1:2 (age, sex, prosthesis position) to patients whose prostheses were explanted because of structural failure (SF). PVD was defined as a 50% increase above baseline gradient at valve implantation and classified as early (≤5 years) or late (>5 years) after implantation.

RESULTS

There were 94 BPVT (51 suspected, 43 confirmed) and 188 SF cases; patient age 61 ± 9 years; men 61 (65%). The prosthesis positions were aortic 56%; mitral 26%; tricuspid 15%; and pulmonary 3%. Early PVD was more common in the BPVT versus SF group: 83 of 94 (88%) versus 20 of 188 (11%) (p < 0.001). Time from implantation to PVD was shorter for BPVT than SF: 26 months (interquartile range [IQR]: 12 to 43 months) versus 74 months (IQR: 48 to 102 months) (p < 0.001). At the initial PVD diagnosis, 81% of BPVT and 90% of SF patients were asymptomatic. However, BPVT patients had rapid symptomatic deterioration, requiring intervention sooner after PVD diagnosis: 6 months (IQR: 4 to 7 months) versus 51 months (IQR: 22 to 55 months) (p < 0.001).

CONCLUSIONS

Most patients with PVD due to BPVT were asymptomatic at initial diagnosis, which was made based on routine surveillance TTE, often performed before 5 years. BPVT, an acute disease process, requires timely diagnosis because patient conditions rapidly deteriorate. Further studies are needed to determine whether routine surveillance TTE should be considered for patients with bioprosthetic valves to identify pre-symptomatic features of BPVT in order to provide effective, appropriate therapy.

Для цитирования: Egbe Alexander, Pislaru Sorin V, Ali Mahmoud A, Khan Arooj R, Boler Amber N, Schaff Hartzell V, Akintoye Emmanuel, Connolly Heidi M, Nkomo Vuyisile T, Pellikka Patricia A. Early Prosthetic Valve Dysfunction Due to Bioprosthetic Valve Thrombosis: The Role of Echocardiography.. JACC. Cardiovascular imaging. 2017. DOI: 10.1016/j.jcmg.2017.06.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.