DOI 10.1007/s12020-025-04311-x
Normotensive primary aldosteronism in a patient with myasthenia gravis: a localization diagnostic conundrum unraveled by 68Ga-pentixafor PET/CT - a case report with review of literature.
Аннотация
PURPOSE: While primary aldosteronism (PA) is typically screened in hypertensive patients, normotensive PA remains underrecognized, especially in complex cases where standard diagnostic approaches fail. We present a challenging case of normotensive PA complicated by myasthenia gravis (MG) requiring chronic glucocorticoids, which interfere with conventional cortisol-based adrenal venous sampling (AVS) interpretation. This case highlights the pivotal role of 68Ga-pentixafor PET/CT as an innovative alternative for subtype differentiation in such complex scenarios.
METHODS
A 30-year-old normotensive woman with MG (on long-term glucocorticoids) was incidentally found to have a left adrenal adenoma. Biochemical testing confirmed PA (elevated ARR, positive captopril challenge test and saline infusion test). Due to glucocorticoid interference with AVS interpretation, 68Ga-pentixafor PET/CT was utilized for precise localization. We further reviewed literature on alternative diagnostic strategies for PA when conventional cortisol-based AVS interpretation is compromised.
RESULTS
68Ga-pentixafor PET/CT successfully localized the aldosterone-producing adenoma, guiding laparoscopic adrenalectomy. Postoperatively, the patient achieved complete biochemical remission (normalized ARR and potassium). To our knowledge, this is the first reported use of 68Ga-pentixafor PET/CT for PA subtype diagnosis in a glucocorticoid-dependent normotensive patient, offering a paradigm for similar challenging cases.
CONCLUSIONS
For PA patients with confounding factors affecting cortisol-based AVS interpretation (e.g., chronic glucocorticoid use), 68Ga-pentixafor PET/CT emerges as a robust non-invasive alternative for accurate subtype differentiation. This case provides a novel diagnostic framework for complex PA presentations, advocating for tailored imaging strategies to overcome traditional limitations.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.