MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2016.12.063

Медицинская библиотека · Journal of shoulder and elbow surgery · 2017

Partial-thickness tears involving the rotator cable lead to abnormal glenohumeral kinematics.

Pinkowsky Gregory J, ElAttrache Neal S, Peterson Alexander B, Akeda Masaki, McGarry Michelle H, Lee Thay Q

СтатьяПеревод в очереди

Аннотация

HYPOTHESIS: The objective of this study was to determine the biomechanical function of the rotator cable when a partial-thickness (>50%) tear is present. We compared intact specimens with partial tears of the anterior cable followed by partial anterior and posterior tears in regard to glenohumeral kinematics and translation. The hypothesis was that partial-thickness tears will lead to abnormal glenohumeral biomechanics, including glenohumeral translation and path of glenohumeral articulation.

METHODS

Five fresh frozen cadaveric shoulders with intact labrum, rotator cuff, and humerus were tested using a custom shoulder testing system in the scapular plane. Glenohumeral translation was measured after applying an anterior load of 30 N at different angles of external rotation. The path of glenohumeral articulation was measured by calculating the humeral head center with respect to the glenoid articular surface at 30°, 60°, 90°, and 120° of external rotation.

RESULTS

With an anterior force of 30 N, there was a significant increase in anterior and total translation at 30° of external rotation after the anterior cable was cut (P < .05). When the tear was extended to the posterior cable, there was a significant increase in anterior, inferior, and total translation at 30° and 120° of external rotation (P < .05). With respect to the path of glenohumeral articulation , the humeral head apex was shifted superiorly at 90° and 120° of external rotation after the posterior cable was cut (P < .05).

CONCLUSION

Partial-thickness articular-sided rotator cuff tears with a thickness >50% involving the rotator cable increased glenohumeral translation and changed kinematics in our cadaveric biomechanical model.

Для цитирования: Pinkowsky Gregory J, ElAttrache Neal S, Peterson Alexander B, Akeda Masaki, McGarry Michelle H, Lee Thay Q. Partial-thickness tears involving the rotator cable lead to abnormal glenohumeral kinematics.. Journal of shoulder and elbow surgery. 2017. DOI: 10.1016/j.jse.2016.12.063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.