DOI 10.1186/s12903-026-09230-5
Comparative finite element analysis of 3-unit implant-supported bridges restorated with different prosthetic materials in posterior mandible.
Аннотация
BACKGROUND
The aim of this study was to investigate the mechanical behaviour and stress distribution characteristics of different prosthetic materials (Co-Cr/porcelain; Zirconia/porcelain; Fibre- reinforced composite/Composite) used in mandibular posterior implant-supported fixed prostheses using finite element analysis (FEA), with particular emphasis on the influence of material stiffness under different loading conditions.
METHODS
Three-dimensional finite element models of a mandibular first premolar and first molar were constructed. Implant-supported fixed prosthetic restorations were simulated using three different restorative materials: metal-supported porcelain (MP), zirconia-supported ceramic (ZP), and fibre-reinforced composite (Trinia-composite, TC). Vertical and oblique occlusal loads were applied to the models. Maximum principal stress, minimum principal stress, and Von Mises stress values were calculated to evaluate stress distribution within the restorative materials and supporting structures.
RESULTS
Across all models, oblique loading resulted in higher stress concentrations compared with axial loading. The first premolar models exhibited higher stress levels than the first molar models under identical loading conditions. The mechanical behaviour and stress distribution in the fixed prostheses were influenced by the prosthetic material used. Restorations fabricated with MP and ZP demonstrated higher stress values than those restored with TC. The fibre-reinforced composite material showed a more homogeneous stress distribution, indicating a more favourable load-transfer behaviour.
CONCLUSIONS
All tested materials generated stress values within physiological limits. The fibre-reinforced polymer-based restoration exhibited improved stress redistribution, most likely due to its elastic compatibility peri-implant structures. These findings suggest that fibre-reinforced composites may offer biomechanical advantages in posterior implant-supported restorations.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.