MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15569845231185346

Медицинская библиотека · Innovations (Philadelphia, Pa.) · 2023

Three-Dimensional Finger Test: A New Echocardiographic Method to Locate the Best Access Site During NeoChord Procedure.

Vairo Alessandro, Manai Rossella, Gaiero Lorenzo, Desalvo Paolo, Bellettini Matteo, Zaccaro Lorenzo, Rinaudo Andrea, Franchin Luca, Piroli Francesco, Bruno Francesco, Sebastiano Viviana, Cura Stura Erik, Barbero Cristina, Marro Matteo, Faletti Riccardo, Alunni Gianluca, De Ferrari Gaetano Maria, Rinaldi Mauro, Salizzoni Stefano

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Transventricular beating-heart mitral valve repair (TBMVR) with artificial chordae implantation is a technique to treat mitral valve prolapse. Two-dimensional (2D) echocardiography completed with simultaneous biplane view during surgeon finger pushing on the left ventricular (LV) wall (finger test [FT]) is currently used to localize the desired LV access, on the inferior-lateral wall, between the papillary muscles (PMs). We aimed to compare a new three-dimensional (3D) method with conventional FT in terms of safety and better localization of LV access.

METHODS

During TBMVR, conventional FT was completed using 3D transesophageal echocardiography by placing the sample box in the bicommissural view of the LV, including the PMs and the apex. The 3D volume was subsequently edited to visualize the LV from above (surgical view) to localize the bulge of the operator's finger pushing on the LV. We asked the first operator, the second operator, and the cardiac surgery fellow, separately, to evaluate the location of their finger pushing, both with the 2D method and the 3D method, to estimate the interoperator concordance.

RESULTS

From 2019 to 2021, 42 TBMVRs were performed without complications related to access using FT completed with the 3D method. Regarding the choice of the right and safe entry site, the operator's agreement was higher using 3D rendering compared with conventional FT (mean agreement 0.59 ± 0.29 for 2D vs 0.83 ± 0.20 for 3D), while full operator agreement was 10 of 42 for 2D and 23 of 42 for 3D (P = 0.004).

CONCLUSIONS

Three-dimensional FT is easy to perform and facilitates surgeons choosing the best access for TBMVR in term of anatomical localization and safety.

Для цитирования: Vairo Alessandro, Manai Rossella, Gaiero Lorenzo, Desalvo Paolo, Bellettini Matteo, Zaccaro Lorenzo, Rinaudo Andrea, Franchin Luca, Piroli Francesco, Bruno Francesco, Sebastiano Viviana, Cura Stura Erik, Barbero Cristina, Marro Matteo, Faletti Riccardo, Alunni Gianluca, De Ferrari Gaetano Maria, Rinaldi Mauro, Salizzoni Stefano. Three-Dimensional Finger Test: A New Echocardiographic Method to Locate the Best Access Site During NeoChord Procedure.. Innovations (Philadelphia, Pa.). 2023. DOI: 10.1177/15569845231185346.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.