m+Medelevator.RU
← Поиск публикаций
Talanta · 2025

An automated magnetic-bead-assisted liquid chromatography-tandem mass spectrometry method for analyzing angiotensins, ALD, and 18-OH derivatives: Application of primary aldosteronism early screening and subtyping.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Bingchu, Liu Zhenni, Qin Nijiao, Li Binghui, Chen Zhiyang, Li Ziyang, Lyu Xing, Tan Li, Guo Zhe, Wu Weimin, Xiang Zhongyuan, Liu Zhendong, Long Qichen, Hu Min

Аннотация

Angiotensin I and II (Ang I, Ang II), aldosterone (ALD), 18-hydroxycorticosterone (18-OHB), 18-hydroxycortisol (18-OHF), and 18-oxocortisol (18-OXOF) are critical biomarkers for the screening, confirming, and subtyping of primary aldosteronism (PA). Liquid chromatography-tandem mass spectrometry (LC-MS/MS) enables simultaneous quantification of multiple analytes; however, obstacles such as labor-intensive manual procedures, complex biological matrices, structural analog interference, and the physicochemical diversity of target analytes limit its application and promotion in clinical laboratories. This study established and validated a robust LC-MS/MS method based on automated magnetic-bead-assisted sequential extraction (MBASE) for the simultaneous detection and quantitation of Ang I, Ang II, ALD, 18-OHB, 18-OHF, and 18-OXOF. The method achieved complete chromatographic resolution with no interference from endogenous hormones or exogenous medications. The analytical recoveries ranged from 86.14 % to 112.89 %, with total imprecisions between 2.93 % and 12.89 %. The MBASE demonstrated a strong correlation with traditional SPE for all six analytes (R: 0.967-0.997), with biases ranging from -4.0 % to 5.1 %. Compared to traditional SPE process, the MBASE workflow reduced total processing time by 46 % and manual handling time by 77 %. The clinical application of this LC-MS/MS method indicated that Ang I and Ang II are effective screening biomarkers, and ALD, 18-OHB, 18-OHF, and 18-OXOF could be used to differentiate PA subtypes. Overall, the newly developed MBASE-LC-MS/MS method exhibits excellent performance and significant advantages for PA diagnosis. It can be a promising tool in the early screening and subtyping for PA and enhance automated mass spectrometry processes in clinical application.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты